| Troubleshooting |
|
|
|
|
|
|
|
| Problem |
| Cause |
| Solution | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sprayer sprays with poor results |
| Spray tip is partially clogged |
| See Unclogging Spray Tip/Guard Assembly, | ||
|
|
|
|
|
| page 14. |
|
|
|
|
|
|
|
|
|
|
| Spray tip is not in correct position |
| Rotate spray tip to SPRAY position. |
|
|
|
|
|
|
|
|
|
|
| Incorrect spray tip for application of |
| See Reversible Spray Tip Selection Chart, |
|
|
|
| material. |
| page 12. |
|
|
|
|
|
|
|
|
|
|
| Spray tip filter is partially clogged or damaged. | Clean or replace spray tip filter. See page 14. | |
|
|
|
|
|
|
|
|
|
|
| Flexible suction tube strainer is partially |
| Clean or replace flexible suction tube. See page |
|
|
|
| clogged. |
| 15. |
|
|
|
|
|
|
|
|
|
|
| Spray tip is worn or damaged |
| Replace spray tip. See Install Spray Tip/Guard |
|
|
|
|
|
| Assembly, page 13. |
|
|
|
|
|
|
|
|
|
|
| Material being sprayed is aerated because it | Do NOT shake material. Stir the material or | |
|
|
|
| was shaken. |
| check the manufacturer’s recommendation for |
|
|
|
|
|
| the material being sprayed. |
|
|
|
|
|
|
|
|
|
|
| Pressure control knob is too low. |
| Turn up pressure control knob. |
|
|
|
|
|
|
|
|
|
|
| Material being sprayed is too cold to spray. |
| Warm material. |
|
|
|
|
|
|
|
|
|
|
| Inlet or outlet valve fittings are worn. |
| See Outlet Valve Fitting Repair, page 22 and |
|
|
|
|
|
| Inlet Valve Removal/Service, page 21. |
|
|
|
|
|
|
|
Paint leaks from sprayer trigger area. |
| Pump has reached its maximum life. |
| Replace pump. | ||
|
|
|
|
|
|
|
Spray Pattern Diagnostics |
|
| ||||
|
|
|
|
|
|
|
| Problem |
| Cause |
| Solution | |
|
|
|
|
| ||
|
|
|
|
| ||
Spray pattern is pulsating: | Operator is moving too fast while spraying. | Slow speed of movement. | ||||
|
|
|
|
| ||
|
|
| Spray tip or spray tip filter is clogged. | Unclog spray tip or clean spray tip filter, page 14. | ||
|
|
|
|
| ||
Spray pattern has tails: | Pressure control knob is too low. | Turn up pressure control knob. | ||||
|
|
|
|
| ||
|
|
| Incorrect spray tip for application of | See Reversible Spray Tip Selection Chart, page 12. | ||
|
|
| material. |
|
| |
|
|
|
|
| ||
|
|
| Material not compatible with sprayer. | Switch material. | ||
|
|
|
|
| ||
| ti15526a | Inlet or outlet valve fittings are worn. | See Outlet Valve Fitting Repair, page 22 and Inlet | |||
|
|
| Valve Removal/Service, page 21. | |||
|
|
|
|
| ||
Spray pattern has dripping: | Sprayer is moving too slow for material. | Move sprayer faster while spraying. | ||||
|
|
|
|
| ||
|
|
| Sprayer is too close to target surface. | Move sprayer away from surface 10 in. (25 cm) | ||
|
|
|
|
| ||
|
|
| Holding trigger while changing spray | Release trigger when changing directions. | ||
|
|
| direction. |
|
| |
|
|
|
|
| ||
|
|
| Incorrect spray tip for application of | See Reversible Spray Tip Selection Chart, page 12. | ||
|
|
| ||||
|
|
| material. |
|
| |
|
|
|
|
| ||
|
|
| Pressure control knob is too high. | Turn down pressure control knob. | ||
|
|
|
|
| ||
|
|
| Spray tip is worn or damaged. | Replace spray tip. See Install Spray Tip/Guard | ||
|
|
|
|
| Assembly, page 13. | |
|
|
|
|
|
|
|
3A2587H | 25 |