Starting a New Job
(or Refilling the Material Cup)
1.Engage trigger lock and put prime/spray valve UP to release pressure.
Starting a New Job (or Refilling the Material Cup)
If sprayer fails to prime, try one of the steps below:
1.Use the Pump Armor storage/startup tool to clean the inlet valve fitting. See Storage, page 17.
ti18912a | ti16700a | ti14999a |
ti14994a |
|
2.Install material cup liner, fill with material, and thread onto sprayer.
ti15474a
ti15551a
3.To fill sprayer with fluid, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/spray valve DOWN to spray position.
ti19536a
2.Clean air vent holes. See Shutdown and Cleaning, page 15.
Use a soft brush to clean the black rubber inlet seal. If air vent holes become clogged, use a paper clip to clean the holes.
ti14995a | ti15418ati16716a | ti15425a |
ti18913a |
| ti16701a |
4. Reverse spray tip to UNCLOG position. Pull trigger
and release. | ti17323a |
|
ti14777a
ti15012a
5. Put prime/spray valve UP to release pressure. Then rotate spray tip back to spray position.
NOTE: Failure to perform this operation could result in poor spray pattern.
ti16700a | ti14778a |
ti17326a