Graco 3A2587H Grounding, Extension Cords, Extension Cord Gauge Extension Cord Length AWG Minimum

Page 3

Warnings

Warnings

The following warnings are for the setup, use, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these sym- bols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

GROUNDING

This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper installation of the grounding plug is able to result in a risk of electric shock.

When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.

The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.

Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.

This product is for use on a nominal 120 V circuit and has a grounding plug similar to the plug illustrated in the figure below.

Ground

ti4295a

Only connect the product to an outlet having the same configuration as the plug.

Do not use an adapter with this product.

Extension Cords:

• Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that accepts the plug on the product.

• Make sure your extension cord is not damaged. When using an extension cord, be sure to use a cord heavy enough to carry the current that your sprayer draws. See chart for appropriate sizes and lengths:

Extension Cord Gauge

Extension Cord Length

(AWG Minimum)

(Maximum)

 

 

18

50 ft (15 m)

 

 

16

100 ft (30 m)

 

 

14

200 ft (61 m)

• An undersized extension cord will result in a drop in line voltage and loss of power, overheating, and possible damage to equipment.

3A2587H

3

Image 3
Contents Model Voltage Description Adjustable Pressure Fixed PressureTable of Contents Grounding Extension CordsExtension Cord Gauge Extension Cord Length AWG Minimum Fire and Explosion Hazard Electric Shock HazardSkin Injection Hazard Toxic Fluid or Fumes Hazard Equipment Misuse HazardPressurized Aluminum Parts Hazard Moving Parts HazardComponent Identification Extension Cord Requirements Using Electrical CordsPower Cord Grounding and Electrical RequirementsTrigger Locked Pressure Relief ProcedureTrigger Lock Prime/Spray ValveNot available on all units Reversible Spray TipPressure Control Knob Flexible Suction TubeOverheating Protection Sprayer SetupIf sprayer fails to prime, try one of the steps below Starting a New Job Or Refilling the Material CupSelecting Tip Hole Size Choosing Pressure Control Knob SettingChoosing the Correct Tip Understanding Tip NumberInstall Spray Tip/Guard Assembly if not installed Getting Started with Basic TechniquesTriggering Sprayer Unclogging Spray Tip/Guard Assembly Aiming SprayerSpray Pattern Quality Flushing Sprayer Shutdown and CleaningTi15529ati18926a Storage Cleaning Sprayer ExteriorModels 16N658, 16N659, 16N673, 17C810 Replacement PartsDescription Parts List Models 16N658, 16N659, 16N673, 17C810Model 16N659, 16N673, 17C810 16M873 Installation Inlet Valve Fitting Removal/ServiceRemoval Outlet Valve Fitting RepairWiring General ServiceProblem Cause Solution TroubleshootingMaterial Spray Pattern DiagnosticsSee Shutdown and Cleaning, Problem Cause Solution Troubleshooting LeaksHand-Held Sprayer Models 16N673, 16N659 Metric Technical DataHand-Held Sprayer Model 16N658 Metric Mark Dial Preferred Material Settings LogDate Material Spray Pressure Setting Example3A2587H Graco Information Graco Standard Warranty