Graco 3A0420T important safety instructions Setup, Location, Grounding

Page 18

Setup

Setup

Location

The XP35, XP50, and XP70 systems are approved for use in hazardous locations only if the base model, all accessories, all kits, and all wiring meet local, state, and national codes.

1.Locate the proportioner on a level surface.

2.Position the proportioner for convenient operator access and maintenance, safe routing of air and fluid lines, and easy connection of components and accessories.

3.For permanent mounting, remove wheels and mount the frame to the floor. See Dimensions, page 58.

4.Ensure that the cart brake (L) is in the locked posi- tion.

Grounding

The equipment must be grounded. Grounding reduces the risk of static and electric shock by pro- viding an escape wire for the electrical current due to static build up.

Pump: use ground wire and clamp (supplied). Loosen grounding lug locknut (W) and washer (X). Insert ground wire end (Y) into lug (Z) slot and tighten locknut securely. Connect ground clamp to a true earth ground.

Y

W, X, Z

Solvent Pump: use ground wire and clamp (supplied with solvent pump). Follow instructions in pump manual.

Air and fluid hoses: use only static dissipation type hoses with a maximum of 500 ft (150 m) combined hose length to ensure grounding continuity. Check electrical resistance of hoses regularly. If total resistance to ground exceeds 29 megohms, replace hose immedi- ately.

Air compressor: follow manufacturer’s recommenda- tions.

Spray gun: ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: follow local code.

Object being sprayed: follow local code.

Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts grounding continuity.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun

firmly to the side of a grounded metal pail, then trigger the gun.

18

3A0420T

Image 18
Contents XP Proportioners Contents Related Manuals Fire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Changing Materials B Component DesignationsEquipment Designations Overview UsageOver Pressure Protection Initial System Setup Models Cart-Mounted SystemsPump Volume Max Fluid Max Air Mix Gallon Packages Bare Proportioning Pump PackagesBuilding systems with bare proportioning pump Over Pressure Protection must be used, seeComponent Identification Mounting Components forFluid Control Assembly Main Air ControlsSolvent Flush Pump Kit 262393 optional Pump KeyAir Controls Optional Accessories Fluid Line AccessoriesFlush Before Using Equipment Air LineSetup LocationGrounding Wire Systems with Explosion-Proof Heaters Hazardous location systems onlyMotor Position Check Motor PositionChange Motor Position Connect Air Supply Connect Fluid Hose Bundles Remote Mix Manifold OnlyConnect Static Mixers, Gun, and Hoses Pressure Relief Procedure Relieve a and B Fluid PressurePrime Empty System Prime a and B FluidsPrime Solvent Flush Pump Heat Fluid Follow Prime Empty System,Spray To Adjust the Restrictor Side Mix Manifold RestrictionFlush Mix Manifold, Hose, and Spray Gun Follow Pressure Relief Procedure,Flush Mixed Material Use Optional Solvent PumpProcedure GuidelinesShutdown ParkSystem Verification Maintenance Troubleshooting Problem Cause SolutionTrouble Area Resin Pump Leakage Pump TroubleshootingHardener Pump Falling Resin PumpRemove Displacement Pump Pump AssemblyRemove Pump Assembly RepairReplace Air Filter Element Replace Air Control AssemblyRemove Motor Replace System Air RegulatorAir Control Assembly Air FlowMix Manifold Assembly Fluid Circulation Manifold with Over Pressure Relief ValvesReplace Over Pressure Relief Valves Target Opening Manifold Valve Fluid Circulation Manifold Replacement GuideCirculation Pressure Color Psi MPa, bar Use withHoppers Optional Solvent PumpService and Repair Optional Fluid HeatersReplace Parts Cart-Mounted SystemStandard Mix Manifold Models Quickset Mix Manifold Models Parts Common to All Systems Description Qty WasherParts Varying By Model XP35 Systems Ref Part Description Coupling 283101 283102 283201 283202 283301 283302 283401 283402 Parts Varying By Model XP70 Systems Part Description Bare Proportioning Pump Package Model 571100 shownParts Common to All Pump Packages Parts Varying by Pump PackageAir Controls Qty Ref. No. Part No. DescriptionPart Description Qty Ref Assembly 262784 XP35 262783 XP50 262806 XP70Fluid Circulation Manifold with Over Pressure Relief Valve Manifold to also fit Series a XP Proportioners withPump Filter O-rings packs Recommended Spare PartsPump Repair Kits Recirculation/Overpressure valve seeAccessories and Kits Acceptable For Use in Explosive AtmospheresNot Approved For Explosive Atmospheres Technical Data Dimensions Top ViewSide View Floor Mounting Dimensions, Top View Bare Proportioner Mounting Hole Dimensions Wall Mount Bracket 262812 Dimensions Floor Stand 24M281 Dimensions Hydraulic Unit DimensionsDimensions 3A0420T Graco Standard Warranty Graco Information