Setup
Motor Position
The motor position must be set for the volume mix ratio of the system.
NOTE: Changing the motor position does not change the mix ratio.
Check Motor Position
1.Verify that the correct pumps are mounted for your mix ratio by volume. See chart in Bare Proportion- ing Pump Packages on page 13.
indicator line
| indicator line |
Air Motor shown | r_258914_3a0420a_10b |
| |
FIG. 6: Ratio indicators |
|
2.Verify that the motor position is adjusted correctly
for that mix ratio. See FIG. 6. If not, perform the fol- lowing Change Motor Position procedure.
Change Motor Position
There are specific motor positions for each mix ratio set- ting. To adjust the position of the air motor:
1.Perform Check Motor Position procedure. If posi- tion is incorrect, continue to next step.
2.Loosen the eight fasteners and remove the two pump guards.
Air Motor shown
fastener
pump guard
fastener
pump guard
3.Place wrench on adapter rod (104) then use sup- plied tool to loosen the serrated yoke nut (V) above the yoke (T).
104 | Air Motor shown |
V
T
4. Loosen the three nuts (P2) below the motor tie rods.
E
piston rod
V
P2
T
r_258914_3a0420a_5a
Air Motor shown
FIG. 7
5.Grab the piston rod and slide the position of the motor (E) until the indicator lines are aligned with your ratio. See FIG. 6 and FIG. 7.
NOTICE
Do not hit tie rods (P) with a steel hammer. Damage to the air motor base may result.
6.Tighten the three nuts (P2) and yoke nut (V).
7.Use supplied tool to tighten the yoke nut.
8.Install the pump guards.
20 | 3A0420T |