Graco 3A0420T important safety instructions Check Motor Position, Change Motor Position

Page 20

Setup

Motor Position

The motor position must be set for the volume mix ratio of the system.

NOTE: Changing the motor position does not change the mix ratio.

Check Motor Position

1.Verify that the correct pumps are mounted for your mix ratio by volume. See chart in Bare Proportion- ing Pump Packages on page 13.

indicator line

 

indicator line

Air Motor shown

r_258914_3a0420a_10b

 

FIG. 6: Ratio indicators

 

2.Verify that the motor position is adjusted correctly

for that mix ratio. See FIG. 6. If not, perform the fol- lowing Change Motor Position procedure.

Change Motor Position

There are specific motor positions for each mix ratio set- ting. To adjust the position of the air motor:

1.Perform Check Motor Position procedure. If posi- tion is incorrect, continue to next step.

2.Loosen the eight fasteners and remove the two pump guards.

Air Motor shown

fastener

pump guard

fastener

pump guard

r_258914_3a0420a_4a-1

3.Place wrench on adapter rod (104) then use sup- plied tool to loosen the serrated yoke nut (V) above the yoke (T).

104

Air Motor shown

V

T

r_571101_3a0420a_2a-2

4. Loosen the three nuts (P2) below the motor tie rods.

E

piston rod

V

P2

T

r_258914_3a0420a_5a

Air Motor shown

FIG. 7

5.Grab the piston rod and slide the position of the motor (E) until the indicator lines are aligned with your ratio. See FIG. 6 and FIG. 7.

NOTICE

Do not hit tie rods (P) with a steel hammer. Damage to the air motor base may result.

6.Tighten the three nuts (P2) and yoke nut (V).

7.Use supplied tool to tighten the yoke nut.

8.Install the pump guards.

20

3A0420T

Image 20
Contents XP Proportioners Contents Related Manuals Fire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Equipment Designations Changing MaterialsB Component Designations Over Pressure Protection OverviewUsage Initial System Setup Models Cart-Mounted SystemsPump Volume Max Fluid Max Air Mix Gallon Bare Proportioning Pump Packages Building systems with bare proportioning pumpPackages Over Pressure Protection must be used, seeComponent Identification Mounting Components forFluid Control Assembly Main Air ControlsAir Controls Solvent Flush Pump Kit 262393 optionalPump Key Fluid Line Accessories Flush Before Using Equipment Optional Accessories Air LineGrounding SetupLocation Wire Systems with Explosion-Proof Heaters Hazardous location systems onlyChange Motor Position Motor PositionCheck Motor Position Connect Static Mixers, Gun, and Hoses Connect Air SupplyConnect Fluid Hose Bundles Remote Mix Manifold Only Pressure Relief Procedure Relieve a and B Fluid PressurePrime Empty System Prime a and B FluidsPrime Solvent Flush Pump Heat Fluid Follow Prime Empty System,Spray To Adjust the Restrictor Side Mix Manifold RestrictionFollow Pressure Relief Procedure, Flush Mixed MaterialFlush Mix Manifold, Hose, and Spray Gun Use Optional Solvent PumpProcedure GuidelinesShutdown ParkSystem Verification Maintenance Troubleshooting Problem Cause SolutionPump Troubleshooting Hardener Pump FallingTrouble Area Resin Pump Leakage Resin PumpPump Assembly Remove Pump AssemblyRemove Displacement Pump RepairReplace Air Control Assembly Remove MotorReplace Air Filter Element Replace System Air RegulatorAir Control Assembly Air FlowReplace Over Pressure Relief Valves Mix Manifold AssemblyFluid Circulation Manifold with Over Pressure Relief Valves Fluid Circulation Manifold Replacement Guide CirculationTarget Opening Manifold Valve Pressure Color Psi MPa, bar Use withHoppers Optional Solvent PumpReplace Service and RepairOptional Fluid Heaters Parts Cart-Mounted SystemStandard Mix Manifold Models Quickset Mix Manifold Models Parts Common to All Systems Description Qty WasherParts Varying By Model XP35 Systems Ref Part Description Coupling 283101 283102 283201 283202 283301 283302 283401 283402 Parts Varying By Model XP70 Systems Part Description Bare Proportioning Pump Package Model 571100 shownParts Common to All Pump Packages Parts Varying by Pump PackageAir Controls Qty Ref. No. Part No. DescriptionAssembly 262784 XP35 262783 XP50 262806 XP70 Fluid Circulation Manifold with Over Pressure Relief ValvePart Description Qty Ref Manifold to also fit Series a XP Proportioners withRecommended Spare Parts Pump Repair KitsPump Filter O-rings packs Recirculation/Overpressure valve seeAccessories and Kits Acceptable For Use in Explosive AtmospheresNot Approved For Explosive Atmospheres Technical Data Side View DimensionsTop View Floor Mounting Dimensions, Top View Bare Proportioner Mounting Hole Dimensions Wall Mount Bracket 262812 Dimensions Floor Stand 24M281 Dimensions Hydraulic Unit DimensionsDimensions 3A0420T Graco Standard Warranty Graco Information