Graco 3A0420T important safety instructions Spray

Page 26

Spray

Spray

Wear gloves when using flush solvents and/or if fluid temperature exceeds 110°F (43°C).

NOTE: After the first day of spraying follow Pres- sure Relief Procedure, page 22, and tighten the throat packing nuts on both pumps.

1.If heaters are used, turn them on. To adjust the

heater temperature, refer to the Viscon HP manual for instructions, and the Heat Fluid section, page 25. Circulate as necessary.

2.Close the circulation handle (AC) and the solvent flush valve (AD). Open the dual shutoff handle (AE).

AC

AE

AD

3.Adjust the main air regulator (CB) to 30 psi (0.21 MPa, 2.1 bar).

4.Remove tip. Disengage the trigger lock and trigger the gun into a grounded metal pail. Use a metal pail lid with a hole to dispense through to avoid splash- ing. Dispense out of the mix hose until a well mixed coating flows from the gun.

TI1950a

TI1953a

 

5. Engage the trigger lock. Install the tip on the gun.

TI1949a

6.Adjust the main pump air regulator (CB) to the nec- essary spraying pressure and apply a coating to a test panel.

NOTE: Run system verification tests everyday. See page 31.

7.Excess pressure increases overspray and pump wear.

8.Check and record gauge readings frequently during operation. A change in gauge readings indicates a change in system performance.

NOTE:

A pressure drop occurs during pump stroke changeover. It should be quick and synchro- nous.

Flush the mix manifold as necessary during the day’s operation.

9.Follow Flush Mixed Material, page 28 when you are finished spraying or before potlife expires.

NOTE: Mixed material potlife or working time decreases with increased temperature. Pot life in the hose is much shorter than the dry time of the coating.

26

3A0420T

Image 26
Contents XP Proportioners Contents Related Manuals Fire and Explosion Hazard Skin Injection Hazard Toxic Fluid or Fumes Hazard Important Two-Component Material Information Equipment Designations Changing MaterialsB Component Designations Over Pressure Protection OverviewUsage Initial System Setup Models Cart-Mounted SystemsPump Volume Max Fluid Max Air Mix Gallon Packages Bare Proportioning Pump PackagesBuilding systems with bare proportioning pump Over Pressure Protection must be used, seeComponent Identification Mounting Components forFluid Control Assembly Main Air ControlsAir Controls Solvent Flush Pump Kit 262393 optionalPump Key Optional Accessories Fluid Line AccessoriesFlush Before Using Equipment Air LineGrounding SetupLocation Wire Systems with Explosion-Proof Heaters Hazardous location systems onlyChange Motor Position Motor PositionCheck Motor Position Connect Static Mixers, Gun, and Hoses Connect Air SupplyConnect Fluid Hose Bundles Remote Mix Manifold Only Pressure Relief Procedure Relieve a and B Fluid PressurePrime Empty System Prime a and B FluidsPrime Solvent Flush Pump Heat Fluid Follow Prime Empty System,Spray To Adjust the Restrictor Side Mix Manifold RestrictionFlush Mix Manifold, Hose, and Spray Gun Follow Pressure Relief Procedure,Flush Mixed Material Use Optional Solvent PumpProcedure GuidelinesShutdown ParkSystem Verification Maintenance Troubleshooting Problem Cause SolutionTrouble Area Resin Pump Leakage Pump TroubleshootingHardener Pump Falling Resin PumpRemove Displacement Pump Pump AssemblyRemove Pump Assembly RepairReplace Air Filter Element Replace Air Control AssemblyRemove Motor Replace System Air RegulatorAir Control Assembly Air FlowReplace Over Pressure Relief Valves Mix Manifold AssemblyFluid Circulation Manifold with Over Pressure Relief Valves Target Opening Manifold Valve Fluid Circulation Manifold Replacement GuideCirculation Pressure Color Psi MPa, bar Use withHoppers Optional Solvent PumpReplace Service and RepairOptional Fluid Heaters Parts Cart-Mounted SystemStandard Mix Manifold Models Quickset Mix Manifold Models Parts Common to All Systems Description Qty WasherParts Varying By Model XP35 Systems Ref Part Description Coupling 283101 283102 283201 283202 283301 283302 283401 283402 Parts Varying By Model XP70 Systems Part Description Bare Proportioning Pump Package Model 571100 shownParts Common to All Pump Packages Parts Varying by Pump PackageAir Controls Qty Ref. No. Part No. DescriptionPart Description Qty Ref Assembly 262784 XP35 262783 XP50 262806 XP70Fluid Circulation Manifold with Over Pressure Relief Valve Manifold to also fit Series a XP Proportioners withPump Filter O-rings packs Recommended Spare PartsPump Repair Kits Recirculation/Overpressure valve seeAccessories and Kits Acceptable For Use in Explosive AtmospheresNot Approved For Explosive Atmospheres Technical Data Side View DimensionsTop View Floor Mounting Dimensions, Top View Bare Proportioner Mounting Hole Dimensions Wall Mount Bracket 262812 Dimensions Floor Stand 24M281 Dimensions Hydraulic Unit DimensionsDimensions 3A0420T Graco Standard Warranty Graco Information