Graco 258866. 258863. 3A0159E, 258875, 258870 important safety instructions Ti14991a

Page 17

Shutdown and Cleaning

7.Discard contaminated fluid and refill with appropri- ate flushing fluid.

8.Disengage trigger lock, reverse tip to UNCLOG position, and pull trigger for 5 seconds to prepare sprayer.

11.Remove material cup and discard used fluid.

12.Use a soft brush to clean the black rubber inlet seal. If the vent holes become clogged, use the Fine Fin- ish Optimizer cleaning tool or a paper clip to clear the holes.

ti14991a

9.Put control lever DOWN to spray position. Trigger sprayer into waste area until no paint appears in water or flushing fluid.

ti15425a

ti15491a

To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the con- tainer when flushing.

ti15529a

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

10.Engage trigger lock and put control lever UP to release pressure.

13.Remove Spray Tip/Guard Assembly and clean with water or flushing fluid. A soft brush can be used to loosen and remove dried material if needed. Run underwater and use a soft brush to clean the filter.

NOTICE

The tip is a permanently attached to the guard. Removing the tip from the guard will result in damage to tip assembly.

14.Replace tip assembly.

15.If you used the Fine-Finish Optimizer, remove and clean optimizer with water (or flushing fluid) and a brush. Reconnect intake tube.

3A0159E

17

Image 17
Contents 3A0159E Table of Contents Extension Cord Gauge Extension Cord Length Extension CordsFire and Explosion Hazard Equipment Misuse Hazard TrueCoat Component Identification TrueCoat Plus Component Identification Power Cord Using Electrical CordsGrounding and Electrical Requirements Extension Cord RequirementsControl Lever Position Pressure Relief ProcedureTrigger Lock Installing Suction Tube SetupCleanup/Storage Overheating ProtectionSprayer Setup Starting a New Job or Refilling the Cup MaterialsThin Medium Heavy Shoulder Strap InstallationReversible Tip Selection Chart Aiming Sprayer Triggering SprayerUnclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningTi14991a Tips Cleaning Sprayer ExteriorStorage Part Replacement Parts and KitsRef. Part Problem Cause Solution TroubleshootingSpray Pattern Diagnostics Problem Cause Solution See Install Tip/Guard Assembly, See Reversible Tip Selection ChartSee Shutdown and Cleaning, Alternate Priming Method Removal Inlet Valve CleaningInstallation Sprayer Technical DataTechnical Data Technical Data 3A0159E Graco Information Graco Standard Warranty