Graco 258870, 258875, 258866. 258863. 3A0159E Shutdown and Cleaning, Flushing Sprayer

Page 16

Shutdown and Cleaning

NOTICE

Failure to properly clean sprayer after each use will result in hardened materials, damage to the sprayer, and the warranty will no longer be valid.

Flushing Sprayer

Use only water-based or oil-based (mineral spirit-type) materials with flash point greater than 100° F (38° C). Do not use materials which state “FLAMMABLE” on the packaging. For more information about your material, request MSDS from distributor or retailer.

Use oil-based material outdoors or in a well-ventilated indoor area with a flow of fresh air.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

NOTICE

Protect the internal parts of this sprayer from water.

Do not submerge the sprayer in cleaning fluid. Openings in shroud allow cooling of mechanical parts and electron- ics inside. If water gets into these openings, the sprayer could malfunction or become permanently damaged.

1.Engage trigger lock and pull control lever UP to release pressure.

Shutdown and Cleaning

3.Remove and clean sprayer intake tube and screen with water (or flushing fluid) and a brush every time you flush the sprayer. Reconnect intake tube.

4.Clean cup if not using a liner, and fill with water or appropriate flushing fluid.

5.Reconnect material cup and shake sprayer to move clean water around and clean all areas inside of cup and underside of sprayer.

ti14999a

2.Remove material cup and properly dispose cup liner or excess material.

6.Disengage trigger lock and trigger sprayer for approximately 15 seconds. Engage trigger lock.

16

3A0159E

Image 16
Contents 3A0159E Table of Contents Extension Cords Extension Cord Gauge Extension Cord LengthFire and Explosion Hazard Equipment Misuse Hazard TrueCoat Component Identification TrueCoat Plus Component Identification Using Electrical Cords Power CordGrounding and Electrical Requirements Extension Cord RequirementsTrigger Lock Pressure Relief ProcedureControl Lever Position Setup Installing Suction TubeCleanup/Storage Overheating ProtectionSprayer Setup Materials Starting a New Job or Refilling the CupReversible Tip Selection Chart Shoulder Strap InstallationThin Medium Heavy Triggering Sprayer Aiming SprayerUnclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerTi14991a Storage Cleaning Sprayer ExteriorTips Ref. Part Replacement Parts and KitsPart Troubleshooting Problem Cause SolutionSpray Pattern Diagnostics Problem Cause Solution See Shutdown and Cleaning, See Reversible Tip Selection ChartSee Install Tip/Guard Assembly, Alternate Priming Method Installation Inlet Valve CleaningRemoval Technical Data SprayerTechnical Data Technical Data 3A0159E Graco Standard Warranty Graco Information