Graco 258875, 258870 Extension Cords, Extension Cord Gauge Extension Cord Length

Page 3

Warnings

Warnings

The following warnings are for the setup, use, maintenance, and repair of this equipment. The exclamation point sym- bol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

GROUNDING

This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper installation of the grounding plug is able to result in a risk of electric shock.

When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.

The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.

Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.

This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in the figure below.

Only connect the product to an outlet having the same configuration as the plug.

Do not use an adapter with this product.

Extension Cords:

Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that accepts the plug on the product.

Make sure your extension cord is not damaged. When using an extension cord, be sure to use a cord heavy enough to carry the current that your sprayer draws. See chart for appropriate sizes and lengths:

Extension Cord Gauge

Extension Cord Length

(AWG Minimum)

(Maximum)

 

 

18

50 ft (15 m)

 

 

16

100 ft (30 m)

 

 

14

200 ft (60m)

 

 

An undersized extension cord will result in a drop in line voltage and loss of power, overheating, and possible damage to equipment.

3A0159E

3

Image 3
Contents 3A0159E Table of Contents Extension Cord Gauge Extension Cord Length Extension CordsFire and Explosion Hazard Equipment Misuse Hazard TrueCoat Component Identification TrueCoat Plus Component Identification Extension Cord Requirements Using Electrical CordsPower Cord Grounding and Electrical RequirementsPressure Relief Procedure Trigger LockControl Lever Position Overheating Protection SetupInstalling Suction Tube Cleanup/StorageSprayer Setup Starting a New Job or Refilling the Cup MaterialsShoulder Strap Installation Reversible Tip Selection ChartThin Medium Heavy Aiming Sprayer Triggering SprayerUnclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningTi14991a Cleaning Sprayer Exterior StorageTips Replacement Parts and Kits Ref. PartPart Problem Cause Solution TroubleshootingSpray Pattern Diagnostics Problem Cause Solution See Reversible Tip Selection Chart See Shutdown and Cleaning,See Install Tip/Guard Assembly, Alternate Priming Method Inlet Valve Cleaning InstallationRemoval Sprayer Technical DataTechnical Data Technical Data 3A0159E Graco Information Graco Standard Warranty