Graco Inc 313516C important safety instructions Air Pressure Regulator

Page 17

NOTE: HVLP and Compliant Gun Limits

HVLP Guns: local laws may limit the maximum pressure to 10 psi (70 kPa, 0.7 bar) at the air cap for compliance. See the table on page 7 for maximum HVLP/Compliant manifold inlet pressures. To measure pressure at the air cap, use the appropriate HVLP Pressure Verifica- tion Kit. See Accessories, page 34.

Compliant Guns: See the table on page 7 for maximum HVLP/Compliant manifold inlet pres- sures.

F

ti01997

FIG. 11: Air Pressure Regulator

3.Test the spray pattern atomization while keeping the gun a consistent distance, about 6 to 8 inches (150 to 200 mm), from the test piece.

Check the atomization quality. Increase the gun atomizing air supply pressure with the air pressure regulator in 5 psi (34 kPa, 0.3 bar) increments until you obtain the desired atomization.

NOTE: For the best transfer efficiency, use the lowest setting needed to achieve desired finish quality.

Setup

4.If the spray pattern is too wide or split, reduce the fan air pressure (or slightly close the fan adjustment valve on manifold 288223).

To further control the spray pattern of air- spray guns only, use an alternate air cap. For a list of available air caps, refer to Accessories, page 34.

NOTE: Reducing the fan air pressure to 0 psi (or fully closing the fan adjustment valve) will produce a round pattern.

313516C

17

Image 17
Contents Automatic AirPro Spray Guns Important Safety InstructionsModels ContentsFire and Explosion Hazard Pressurized Equipment Hazard General Metal Applications Selection ChartsWood Applications High Wear ApplicationsGun Selection Hvlp GunsConventional Guns Proper Needle/Nozzle SelectionAir Caps Air Flow Air FlowAtomizing Air Fan Air Maximum HVLP/Compliant inlet manifold pressure Ventilate Spray Booth InstallationConfigure Gun and Manifold Circulating SystemGround System Install Air FittingsStationary Support Mount GunReciprocating Arm Rod Mount Retrofit Adapter Plate Mount Retrofit Adapter PlateConnect Fluid Hose SetupConnect Air Line Position Air Cap Flush Spray GunSuggested Starting Settings Atomization Adjust Spray PatternFan Air psi Spray GunAir Pressure Regulator Operation Pressure Relief ProcedureApply Fluid IncorrectDaily Gun Care Clean and Flush Gun General System MaintenanceProblem Cause Solution TroubleshootingGeneral Troubleshooting Spray Pattern Troubleshooting Disassembly ServiceAlternate Fluid Control Shown Reassembly 17† 21† Alternate Fluid Control 20† 22† 36† 24a 25a PartsGasket Nozzle Repair KitsGeneral Metal Applications Wood Applications High Wear ApplicationsPart Description Qty Manifold with bottom fluid portsPart No C342 Side Fluid Ports and Fan Adjustment ValveNot shown, optional size Not sold separately Part No only Description Qty106 Accessories Inline Fluid Filter 24B707 Hvlp Pressure Verification KitSpray Tip Filters Count Carton Pack DescriptionManifold Model 288221, All Gun Models DimensionsManifold Models 288217 or 288218, All Gun Models Manifold Model 288160 or 288211, All Gun Models Manifold Model 288223 or 24C342, All Gun ModelsMounting Hole Layouts 23.4 mm 10.2 mm 53.3 mm 50 in .7 mm Mounting hole 216 23.4 mm 10.2 mm 27.9 mm 375 in .5 mm Mounting hole Retrofit Adapter Plate Triggering Speed Technical DataSound Data Cylinder Air Fluid Pressure Air Pressure Msec to fullyGraco Headquarters Minneapolis Graco Standard WarrantyGraco Information