Operation

Operation

Pressure Relief Procedure

1.Turn off all bleed type air valves and all other air and fluid supplies to the gun.

2.Trigger the gun into a grounded metal waste container to relieve air and fluid pres- sure.

ti8174a

FIG. 12: Pressure Relief

To achieve best results when applying fluid:

Keep gun perpendicular and 6 to 8 in. (150 to 200 mm) from object being sprayed.

Use smooth, parallel strokes across sur- face to be sprayed with 50% overlap.

Incorrect

ti8098a

Apply Fluid

The spray gun has a built-in lead and lag oper- ation. When triggered, the gun begins emitting air before the fluid is discharged. When the trigger actuation air is stopped, the fluid stops before the air flow stops. This helps ensure that the spray is atomized and prevents fluid buildup on the air cap and tip.

Adjust the system control device, if it is auto- matic, so the gun starts spraying just before meeting the part and stops as soon as the part has passed.

Correct

ti8099a

FIG. 13: Correct Spray Method

18

313516C

Image 18
Contents Important Safety Instructions Automatic AirPro Spray GunsContents ModelsFire and Explosion Hazard Pressurized Equipment Hazard Selection Charts General Metal ApplicationsGun Selection High Wear ApplicationsWood Applications Hvlp GunsProper Needle/Nozzle Selection Air CapsConventional Guns Air Flow Atomizing Air Fan AirAir Flow Maximum HVLP/Compliant inlet manifold pressure Configure Gun and Manifold InstallationVentilate Spray Booth Circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountStationary Support Retrofit Adapter Plate Retrofit Adapter Plate MountSetup Connect Air LineConnect Fluid Hose Flush Spray Gun Position Air CapFan Air psi Adjust Spray PatternSuggested Starting Settings Atomization Spray GunAir Pressure Regulator Apply Fluid Pressure Relief ProcedureOperation IncorrectDaily Gun Care General System Maintenance Clean and Flush GunTroubleshooting General TroubleshootingProblem Cause Solution Spray Pattern Troubleshooting Service DisassemblyAlternate Fluid Control Shown Reassembly Parts 17† 21† Alternate Fluid Control 20† 22† 36† 24a 25aGasket Repair Kits General Metal ApplicationsNozzle High Wear Applications Wood ApplicationsManifold with bottom fluid ports Part Description QtySide Fluid Ports and Fan Adjustment Valve Part No C342Description Qty Not shown, optional size Not sold separately Part No only106 Accessories Spray Tip Filters Hvlp Pressure Verification KitInline Fluid Filter 24B707 Count Carton Pack DescriptionDimensions Manifold Models 288217 or 288218, All Gun ModelsManifold Model 288221, All Gun Models Manifold Model 288223 or 24C342, All Gun Models Manifold Model 288160 or 288211, All Gun ModelsMounting Hole Layouts 23.4 mm 10.2 mm 53.3 mm 50 in .7 mm Mounting hole 216 23.4 mm 10.2 mm 27.9 mm 375 in .5 mm Mounting hole Retrofit Adapter Plate Sound Data Technical DataTriggering Speed Cylinder Air Fluid Pressure Air Pressure Msec to fullyGraco Standard Warranty Graco InformationGraco Headquarters Minneapolis