Graco Inc 313516C important safety instructions General System Maintenance, Clean and Flush Gun

Page 20

Operation

General System Maintenance

Perform Pressure Relief Procedure, page 18.

Clean the fluid and air line filters daily.

Check for any fluid leakage from the gun and fluid hoses. Tighten fittings or replace equipment as needed.

Flush the gun before changing colors and whenever you are done operating the gun.

Clean and Flush Gun

1.Perform Pressure Relief Procedure, page 18.

2.Shut off the gun fan and atomizing air.

3.Supply a compatible solvent to the gun fluid inlet.

4.Point the gun down into a grounded metal container, and flush the gun with solvent until all traces of paint are removed from the gun passages.

5.Perform Pressure Relief Procedure, page 18.

6.Disconnect the solvent supply.

7.Remove the air cap retaining ring and air cap.

NOTICE

Trigger the gun or remove the piston cap whenever you tighten or remove the noz- zle. This keeps the needle seat away from the nozzle seating surface and prevents the seat from being damaged.

8.Clean the air cap retaining ring, air cap, and fluid nozzle with solvent.

9.Dip the end of a soft-bristle brush into a compatible solvent. Do not continuously soak the brush's bristles with solvent and do not use a wire brush.

ti4845a

FIG. 14: Use solvent-dipped soft-bristle brush

10.With the gun pointed down, clean the front of the gun, using the soft-bristle brush and solvent.

11.Scrub the air cap retaining ring, air cap, and fluid nozzle with the soft-bristle brush (see FIG. 15). To clean out air cap holes, use a soft implement, such as a toothpick, to avoid damaging critical surfaces. Clean the air cap and fluid nozzle daily, minimum. Some applications require more frequent cleaning.

ti8176a

FIG. 15: Clean air cap, ring and fluid nozzle

12.Install the air cap retaining ring and air cap.

13.Dampen a soft cloth with solvent and wring out the excess. Point the gun down and wipe off the outside of the gun.

20

313516C

Image 20
Contents Important Safety Instructions Automatic AirPro Spray GunsContents ModelsFire and Explosion Hazard Pressurized Equipment Hazard Selection Charts General Metal ApplicationsHigh Wear Applications Wood ApplicationsGun Selection Hvlp GunsConventional Guns Proper Needle/Nozzle SelectionAir Caps Air Flow Air FlowAtomizing Air Fan Air Maximum HVLP/Compliant inlet manifold pressure Installation Ventilate Spray BoothConfigure Gun and Manifold Circulating SystemInstall Air Fittings Ground SystemStationary Support Mount GunReciprocating Arm Rod Mount Retrofit Adapter Plate Retrofit Adapter Plate MountConnect Fluid Hose SetupConnect Air Line Flush Spray Gun Position Air CapAdjust Spray Pattern Suggested Starting Settings AtomizationFan Air psi Spray GunAir Pressure Regulator Pressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care General System Maintenance Clean and Flush GunProblem Cause Solution TroubleshootingGeneral Troubleshooting Spray Pattern Troubleshooting Service DisassemblyAlternate Fluid Control Shown Reassembly Parts 17† 21† Alternate Fluid Control 20† 22† 36† 24a 25aGasket Nozzle Repair KitsGeneral Metal Applications High Wear Applications Wood ApplicationsManifold with bottom fluid ports Part Description QtySide Fluid Ports and Fan Adjustment Valve Part No C342Description Qty Not shown, optional size Not sold separately Part No only106 Accessories Hvlp Pressure Verification Kit Inline Fluid Filter 24B707Spray Tip Filters Count Carton Pack DescriptionManifold Model 288221, All Gun Models DimensionsManifold Models 288217 or 288218, All Gun Models Manifold Model 288223 or 24C342, All Gun Models Manifold Model 288160 or 288211, All Gun ModelsMounting Hole Layouts 23.4 mm 10.2 mm 53.3 mm 50 in .7 mm Mounting hole 216 23.4 mm 10.2 mm 27.9 mm 375 in .5 mm Mounting hole Retrofit Adapter Plate Technical Data Triggering SpeedSound Data Cylinder Air Fluid Pressure Air Pressure Msec to fullyGraco Headquarters Minneapolis Graco Standard WarrantyGraco Information