Troubleshooting

Troubleshooting

If the gun leaks at the swivel (21), see Swivel

Repair, below.

If the gun leaks at the nozzle, try adjusting the trigger free play. See Needle Adjustment on page 9.

If the leakage is not stopped, the needle (10) or valve14 seat (8) may need to be replaced. See Gun Repair on

page 10.

If the gun leaks at the packing nut (14), check the tightness of the packing nut. Remove the tip guard or nozzle extension. Insert a 0.125 in. (3.18 mm) diame- ter rod into the needle tip and tighten just enough to

stop leakage. See Fig. 3. If leakage is not stopped, the Fig. 3 packings or needle may need to be replaced. See Gun

Repair, page 10.

Safety Off

8125

8 307010

Image 8
Contents Instructions - Parts List Model 208008, Series DHydra-Cleanr Spray Gun 307010L STAINLESS STEELTable of Contents SymbolsWarning Symbol Caution SymbolFIRE AND EXPLOSION HAZARD SKIN INJECTION HAZARDGrounding SetupPressure Relief Procedure Installation Operation Flushing the Gun Adjust the Spray PatternCleaning and Clearing the Spray Tip Troubleshooting Swivel Repair ServiceNeedle Adjustment Gun Repair See Fig Parts 1/4 nptf†24 †23 †25 3/8 nptfTip Selection Charts Blasting Tips and Stainless SteelStainless Steel Included in Repair KitTechnical Data Graco Standard Warranty Graco InformationGRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN Graco reserves the right to make changes at any time without notice