| Advanced Troubleshooting |
|
|
|
|
|
|
|
Specific Problem | Cause | Solution |
|
|
|
|
|
|
|
|
|
|
|
|
Motor runs and pump cycles, | Intake valve or outlet valve is | Remove and clean inlet valves and outlet valves. |
|
|
but pressure does not build up. | not seating properly. | Replace if necessary. See List of Kits, page 26. |
|
|
|
|
|
|
|
| Pump packings are worn or | Check for leaking around pump. |
|
|
| damaged. | ProX7 and ProX9: Replace pump packings. See |
|
|
|
|
|
| |
|
| List of Kits, page 26. |
|
|
|
| X5 and X7: Replace complete pump. See List of |
|
|
|
| Kits, page 26. |
|
|
|
|
|
|
|
|
|
| ||
General Problem: Excessive Pressure Build Up |
|
| ||
|
|
|
|
|
|
|
|
|
|
Specific Problem | Cause | Solution |
|
|
|
|
|
|
|
|
|
|
|
|
Prime/Spray Valve actuates | Pressure control switch has | Replace pressure control switch using Pressure |
|
|
automatically, relieving | pinched wires. | Control Switch Kit, page 26. |
|
|
pressure through drain tube. |
|
|
|
|
Water or paint entered | Use Pressure Control Switch Kit, to replace |
|
| |
|
|
| ||
| pressure control switch or | switch. See List of Kits, page 26. |
|
|
| shorted control board. |
|
|
|
|
|
|
|
|
| Control board failed. | See Control Board Diagnostics, page 25. |
|
|
|
| Replace damaged control board using Control |
|
|
|
| Board Kit, page 26. |
|
|
|
|
|
|
|
22 | 312667B |