Graco Inc 261820 specifications Fire and Explosion Hazard

Page 4

Warnings

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment. For X5 and X7 models: only use water-based or min- eral spirit-type materials with a flash point greater than 70° F (21° C).

Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray sys- tem, including the pump, hose assembly, spray gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.

Verify that all containers and collection systems are grounded to prevent static discharge.

Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.

Do not use a paint or a solvent containing halogenated hydrocarbons.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a well ventilated area. Do not spray pump assembly.

Do not smoke in the spray area.

Do not operate light switches, engines, or similar spark producing products in the spray area.

Keep area clean and free of paint or solvent containers, rags, and other flammable materials.

Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer’s safety instructions.

Fire extinguisher equipment shall be present and working.

Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.

SKIN INJECTION HAZARD

Do not aim the gun at, or spray any person or animal.

Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.

Use Graco nozzle tips.

Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure before removing the nozzle tip to clean.

Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and follow the Pressure Relief Procedure for turning off the unit.

High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, get immediate surgical treatment.

Check hoses and parts for signs of damage. Replace any damaged hoses or parts.

This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are rated a minimum of 3000 psi.

Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.

Verify that all connections are secure before operating the unit.

Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.

4

312667B

Image 4
Contents US Patent 6,752,067 European Patent 1 208 Korean Patent ProX9 Airless Sprayers 312667B Related Manual Getting Started SpecificationsFold-n-StoreCart ProX Sprayers Only Grounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Grounding and Electric Requirements InstallationThermal Overload Component Identification ProX Sprayers OnlyX7, ProX7, and ProX9 Only ProX9 OnlySG20 SG10 Pressure Control Knob Settings Pressure Relief Procedure OperationTrigger Lock Trigger Locked SG10 Trigger Unlocked SG10General Repair Information Basic Troubleshooting Grounding and Electric RequireProX7 and ProX9 Insert screw Read Pump does not prime section ProX7 and ProX9 OnlyGrounding and Electrical Requirements,Grounding and Electrical Advanced Troubleshooting General Problem Motor Does Not OperateSee Control Board Diagnostics, Hazard After Thermal General Problem Circuit Breaker is Tripping Electric Requirements, General Problem Erratic Motor OperationControl. See List of Kits, General Problem Low or Fluctuating Output Switch Kit,See Control Board Diagnostics, page 25. If Prime/Spray Valve Kit,Control Switch Kit, General Problem Excessive Pressure Build UpUse Pressure Control Switch Kit, to replace Motor Diagnostics X5 Motor Diagnostics ProX7 and ProX9Setup Setup Relieve Pressure,Pressure Control Switch Diagnostics ProX7, ProX9, X5,Control Board Diagnostics X5 Control Board Diagnostics ProX7 and ProX9Pump Diagnostics List of Kits Kit Number Models Kit DescriptionParts X5 Model 262800 Parts ListPart Description Qty X5 Model X5, Model X7 Model 262805 Parts List X7 Model 41a 41b 41c 67a 47a 41d 67b 85a ProX7 and ProX9 Models 261815 and 261820 Parts List HUB CAPProX7 and ProX9 Models 261815 ProX7 and ProX9 Models 261810 Wiring Diagrams X5 and X7 Models 262800ProX7 and ProX9 Models 261815 Technical Data Magnum ProX7 Magnum ProX9Graco Standard Warranty For Graco Canada CustomersGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN