Operation
Operation
See Operation manual 312001 for basic information on sprayer
Trigger Lock
Always engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by hand or if dropped or bumped.
ti8923ati8922a
Trigger Locked SG10 | Trigger Unlocked SG10 |
ti8908a | ti8909a |
Trigger Locked SG20 | Trigger Unlocked SG20 |
Pressure Control Knob Settings
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever you stop spraying and before cleaning, checking, servicing, or transporting equipment.
1.Turn power switch OFF and unplug power cord.
ti2018a
2.Turn Prime/Spray valve to PRIME to relieve pressure.
ti9346a
3.Hold gun firmly to side of pail. Trigger the gun to relieve pressure.
4.Engage trigger lock.
ti9207a
Leave Prime/Spray valve in the PRIME position until you are ready to spray again.
If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Clear hose or tip obstruction. Read Unclogging Spray Tip instructions in the Sprayer or Gun Operation manual.
ti5597a
High Pressure | Low Pressure | Prime/ Rolling |
Spray | Spray | Clean |
To select function, align symbol on pressure control knob with setting indicator on sprayer.
312667B | 9 |