Technical Data

Technical Data

 

 

 

 

 

 

 

 

 

MAGNUM X5

MAGNUM X7

MAGNUM ProX7

MAGNUM ProX9

 

 

 

 

 

Working pressure range

0-2800 psi

0-3000 psi

0-3000 psi

0-3000 psi

 

(0-19 MPa, 0-193 bar)

(0-21 MPa, 0-207 bar)

(0-21 MPa, 0-207 bar)

(0-21 MPa, 0-207 bar)

 

 

 

 

 

Electric motor

6.0A

6.0A

5.8A (open frame,

9.4A (open frame,

 

(open frame, universal)

(open frame, universal)

permanent magnet DC)

permanent magnet DC)

 

 

 

 

 

Operating horsepower

1/2

5/8

3/4

7/8

 

 

 

 

 

Maximum delivery (with tip)

0.24 gpm (0.91 lpm)

0.31 gpm (1.17 lpm)

0.34 gpm (1.29 lpm)

0.38 gpm (1.44 lpm)

 

 

 

 

 

Paint hose

1/4 in. x 25 ft

1/4 in. x 25 ft

1/4 in. x 50 ft

1/4 in. x 50 ft

 

(6.4 mm x 7.5 m)

(6.4 mm x 7.5 m)

(6.4 mm x 15 m)

(6.4 mm x 15 m)

 

 

 

 

 

Maximum tip hole size

0.015 in. (0.38 mm)

0.017 in. (0.43 mm)

0.017 in. (0.43 mm)

0.019 in. (0.48 mm)

 

 

 

 

 

Weight, sprayer only

16 lb (7.3 kg)

26 lb (11.8 kg)

43 lb (20 kg)

43 lb (20 kg)

 

 

 

 

 

Weight, sprayer, hose & gun

19.2 lb (8.7 kg)

29.2 lb (13.2 kg)

46 lb (21 kg)

46 lb (21 kg)

 

 

 

 

 

Dimensions (Upright):

 

 

 

 

 

 

 

 

 

Length

14.5 in. (36.8 cm)

19.3 in. (49.0 cm)

23.75 in. (60.32 cm)

23.75 in. (60.32 cm)

 

 

 

 

 

Width

12.4 in. (31.5 cm)

15.3 in. (38.9 cm)

17.5 in. (44.45 cm)

19.25 in. (48.89 cm)

 

 

 

 

 

Height

17.9 in. (45.5 cm)

37.0 in. (94.0 cm)

36.5 in. (92.71 cm)

36.5 in. (92.71 cm)

 

 

 

 

 

Dimensions (Folded):

 

 

 

 

 

 

 

 

 

Length

N/A

19.3 in. (49.0 cm)

23.25 in. (59.05 cm)

23.25 in. (59.05 cm)

 

 

 

 

 

Width

N/A

15.3 in. (38.9 cm)

17.5 in. (44.45 cm)

19.25 in. (48.89 cm)

 

 

 

 

 

Height

N/A

29.2 in. (74.2 cm)

22.00 in. (55.88 cm)

22.00 in. (55.88 cm)

 

 

 

 

 

Power cord

18 AWG, 3-wire, 6 ft (1.8 m)

16 AWG, 3-wire, 6 ft (1.8 m)

 

 

 

 

Fluid inlet fitting

3/4 in. internal thread (standard garden hose thread)

 

 

 

 

Fluid outlet fitting

 

1/4 NPSM external thread

 

 

 

 

 

Inlet screen (on suction tube)

 

35 mesh (450 micron)

 

 

 

Wetted parts, pump & hose

stainless steel, brass, leather, ultra-high molecular weight polyethylene (UHMWPE), carbide,

 

nylon, aluminum, PVC, polypropylene, fluroelastomer

 

 

Wetted parts, gun

aluminum, brass, carbide, nylon, plated steel, stainless steel, UHMWPE, zinc

 

 

 

 

Generator requirement

 

1500 Watt minimum

 

 

 

 

 

Electrical power requirement

 

120 Vac, 60 Hz, 15A, 1 phase

 

 

 

 

 

Storage temperature range ◆❖

 

-30° to 160°F (-35° to 71°C)

 

 

 

 

 

Operating temperature range

 

40° to 115°F (4° to 46°C)

 

 

 

 

 

 

When pump is stored with non-freezing fluid. Pump damage will occur if water or latex paint freezes in pump. Damage to plastic parts may result if impact occurs in low temperature conditions.

Changes in paint viscosity at very low or very high temperatures can affect sprayer performance.

38

312667B

Image 38
Contents Related Manual ProX9 Airless Sprayers 312667BUS Patent 6,752,067 European Patent 1 208 Korean Patent Fold-n-StoreCart ProX Sprayers Only SpecificationsGetting Started Grounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Thermal Overload InstallationGrounding and Electric Requirements X7, ProX7, and ProX9 Only Component IdentificationProX Sprayers Only ProX9 OnlySG20 SG10 Trigger Lock Pressure Control Knob Settings Pressure Relief ProcedureOperation Trigger Locked SG10 Trigger Unlocked SG10General Repair Information Basic Troubleshooting Grounding and Electric RequireProX7 and ProX9 Insert screw Read Pump does not prime section ProX7 and ProX9 OnlyGrounding and Electrical Requirements,Grounding and Electrical Advanced Troubleshooting General Problem Motor Does Not OperateSee Control Board Diagnostics, Hazard After Thermal General Problem Circuit Breaker is Tripping Control. See List of Kits, General Problem Erratic Motor OperationElectric Requirements, See Control Board Diagnostics, page 25. If General Problem Low or Fluctuating OutputSwitch Kit, Prime/Spray Valve Kit,Use Pressure Control Switch Kit, to replace General Problem Excessive Pressure Build UpControl Switch Kit, Setup Motor Diagnostics X5Motor Diagnostics ProX7 and ProX9 Setup Relieve Pressure,Pressure Control Switch Diagnostics ProX7, ProX9, X5,Pump Diagnostics Control Board Diagnostics ProX7 and ProX9Control Board Diagnostics X5 List of Kits Kit Number Models Kit DescriptionPart Description Qty X5 Model 262800 Parts ListParts X5 Model X5, Model X7 Model 262805 Parts List X7 Model 41a 41b 41c 67a 47a 41d 67b 85a ProX7 and ProX9 Models 261815 and 261820 Parts List HUB CAPProX7 and ProX9 Models 261815 ProX7 and ProX9 Models 261810 Wiring Diagrams X5 and X7 Models 262800ProX7 and ProX9 Models 261815 Technical Data Magnum ProX7 Magnum ProX9Graco Standard Warranty For Graco Canada CustomersGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN