| Basic Troubleshooting |
|
|
|
Problem | Cause | Solution |
|
|
|
|
|
|
Pump does not prime. | Prime/Spray Valve is in SPRAY posi- | Turn Prime/Spray Valve to PRIME |
| tion. | position (pointing down). |
|
|
|
| Inlet screen is clogged or suction | Clean debris off inlet screen and |
| tube is not immersed. | make sure suction tube is immersed |
|
| in fluid. |
|
|
|
| Pump was not primed with flushing | Remove suction tube from paint. |
| fluid. | Prime pump with water or |
|
| |
|
| Operation manual 312001. |
|
|
|
| Inlet valve check ball is stuck. | Remove suction tube and place a |
|
| pencil into the inlet section to dis- |
|
| lodge the ball, allowing pump to |
|
| prime properly. Or, Power Flush |
|
| sprayer, see Operation manual |
|
| 312001. |
|
|
|
|
| AutoPrime may need replacement. |
|
| Turn power switch ON and listen for |
|
| “tap” in pump. If you do not hear |
|
| “tap”, AutoPrime is damaged. Take |
|
| sprayer to Graco/MAGNUM autho- |
|
| rized service center. |
|
|
|
| Inlet valve check ball or seat is dirty | Remove inlet fitting. Clean or replace |
|
| ball and seat. |
|
|
|
| Outlet valve check ball is stuck. | ProX7 and ProX9: Insert screw |
|
| driver in slot and remove |
|
| |
|
| outlet valve with a 3/4 in. socket. |
|
| Remove and clean assembly. |
|
| X5 and X7: Remove outlet fitting and |
|
| clean outlet check ball. |
|
|
|
| Suction tube is leaking. | Check suction tube for cracks and |
|
| cuts. Make sure suction tube clamp is |
|
| on hose. Replace suction tube if |
|
| cracked or damaged. |
|
|
|
12 | 312667B |