| Troubleshooting | |
| Troubleshooting |
| |
Pressure Relief, page 7 |
|
| |
|
|
| |
Problem | Cause | Solution | |
|
|
| |
|
|
| |
Sprayer won’t run or stops intermit- | Power switch not on | Turn switch on. | |
tently |
|
| |
No power at wall outlet | Check outlet by plugging in another | ||
| |||
|
| appliance. If appliance does not | |
|
| work, try another outlet. | |
|
|
| |
| Wrong size generator | Use a 7500 watt or larger generator. | |
|
| Refer to Generator Requirements, | |
|
| page 8. | |
|
|
| |
| Temperature too cold | Allow unit to warm up. | |
|
|
| |
| Too many items on same circuit | Unplug other items from circuit. | |
|
|
| |
| Internal thermal switch tripped | ||
|
| 15 minutes and restart. Usually | |
|
| occurs when wrong size extension | |
|
| cord is used. | |
|
|
| |
| Extension cord too long or wrong | Use a 12 gage extension cord or | |
| gauge | remove extension cord. Refer to | |
|
| Grounding and Electric Require- | |
|
| ments, page 7. | |
|
|
| |
| Breaker tripped | Reset breaker. | |
|
|
| |
Pump won’t pump material or low | Air lock | Open air valve on gun. | |
output |
|
| |
Mix too thick | Add water to thin material. Use Mate- | ||
| |||
|
| rial Thickness Gauge. | |
|
|
| |
| Loose fittings | Check and retighten all fittings. | |
|
|
| |
| Plugged gun | Relieve Pressure, page 7. Remove | |
|
| gun from hose. Clean gun. | |
|
|
| |
| RotoFlex HD Pump worn out | Replace hose. | |
|
|
| |
| Pump cold or material frozen in pump | Move pump to warm room and allow | |
|
| it to warm up or run hot water through | |
|
| sprayer. | |
|
|
| |
| Sensor is bad | Replace, page 26 | |
|
|
| |
| Check air system for leaks | Remove shroud and examine for air | |
|
| leaks | |
|
|
| |
| Loose wire | Remove shroud and examine wiring | |
|
|
| |
| No air pressure | Rebuild compressor | |
|
|
| |
Soft start won’t work/pump, always | Sensor is bad | Change sensor, page 26 | |
loaded |
|
| |
Air leak due to bad seal keeps valve | Replace seal | ||
| |||
| open |
| |
|
|
| |
| Normal soft start system delay | Release trigger for | |
|
| Retry. | |
|
|
| |
| Switch is not operating properly | Replace switch | |
|
|
| |
| Damaged solenoid valve on cylinder | Check gun supply, hose and sprayer | |
|
| for leaks | |
| AIr leak | ||
|
| ||
|
|
|
310645H | 27 |