I.C.T.C. Holdings Corporation 1100NC, 1100C owner manual Situation, Electric Motor Wont START/RUN

Page 16

"Diaphragm Test"

The solution to almost all problems can be found in the paint side valves, due to the increased wear from contact with the abrasive paint/spray materials. Intake valve (ref# 16-23) and Outgo valve (ref#32) make up the paint valves. Refer to pages where exploded views of these valves are shown.

To eliminate the hydraulic side of the pump (piston / oil side of diaphragm) as a source of problems;

1.Remove the intake valve end cap (ref# 16) by removing the four cap screws (ref# 14). Set aside the spring (ref# 20 ).

2.Start unit.

3.Increase the pressure by turning the pressure control knob (ref# 71) clockwise to full pressure.

4. Put pressure on the center of the exposed diaphragm with the handle of a screwdriver or other blunt object.

NOTE: The diaphragm is located between the paint head (ref# 23) and the hydraulic head (ref# 51)

5.If you are:

-UNABLEto stop or alter the diaphragm's movement, then the hydraulic side is operating properly. The problem is located in the “Paint” pump. See troubleshooting guide for additional information.

-ABLEto stop or alter the diaphragm's movement, then the hydraulic pump is not operating properly. The problem is located in the “Hydraulic” pump. See troubleshooting guide for additional information.

TROUBLESHOOTING

SITUATION

POSSIBLE CAUSE (REMEDY)

ELECTRIC MOTOR WON'T START/RUN

1.Unit unplugged or building circuit fuse is blown. (check, replace or reset fuse)

16

14

51

23

H.E.R.O. INDUSTRIES

15

1100C & 1100NC OWNERS MANUAL

Image 16
Contents Page R.O. Warranty R.O. IndustriesTable of Contents Important Safety PrecautionsAlways R.O. Airless Spray Painting AlwaysSetting UP to Spray E R a T I N G InstructionsFlushing the Unit AT Shutdown or Color Change Special Notes General Maintenance Instructions Special Storage InstructionsAirless Spray Painting Suggestions and Technique SYSTEM, Even OvernightFor Excellent RESULTS, Read and Practice These Techniques 018 Troubleshooting Orifice SizeTroubleshooting Hydraulic Intake Valve REF# 59 Pressure Test Situation Electric Motor Wont START/RUNElectric Motor STALLS/QUITS No PRESSURE, Blue Hydraulic Fluid in PaintSprayer does not Prime with Paint Puddle of OIL Appearing Under Sprayer During OperationSpray Pattern Leaves Lines or Fingers Spray Pattern is Spotty or Uneven Diaphragm ReplacementExcessive Overspray or Fogging Replacement of Intake Seat REF # RemovalPiston Repairs Outgo Valve REF# Tools Required -1 wrenchREF# Pressure Control Valve Accessories Parts List O L SHOSE, Airless Paint 50 X 1/4 Parts List NEW Style BeginningOutgo Parts 45A TANK, Complete. Includes Ref# Drive Parts SPACER, 1100NC-MD only SPRING, 1100NC-MD only R.O. Industries1100MD Schematic Parts Schematics Authorized Sales and Service Centers U.S.A Authorized Sales and Service CENTERS- U.S.A Southern CaliforniaNEW York Rhode Island R.O. Industries 2719 Lake City WAY BURNABY, B.C Canada