Clean up |
| Site Considerations |
|
|
|
|
|
|
The column and other unpainted parts of the Model G4008/G4009 are coated with a waxy oil that protects them from corrosion during ship- ment. Remove the protective coating with miner- al spirits and paper towels. Do not use gasoline or other petroleum based solvents because of their extremely low flash points. Do not use chlorine- based solvents – if you happen to splash some onto a painted surface, you’ll ruin the finish.
WARNING!
Follow the safety rules listed below when working with solvents:
1.Read and follow all directions and warnings on the solvent label.
2.Work only in a well ventilated area.
3.Do not work near any type of open flame (e.g., pilot lights, kerosene heaters, and so on).
4.DO NOT smoke while working with flamma- ble material.
5.Paper towels from the cleaning process are extremely combustible. Dispose of waste towels so they do not create a fire hazard.
1.Floor Load: Your G4008/G4009 Drill press represents a large weight load in a small footprint. Most commercial floors are suitable for the Model G4008/G4009. Some residen- tial floors may require additional
2.Working Clearances: Consider existing and anticipated needs, size of material to be processed through each machine, and space for auxiliary stands, work tables or other machinery when establishing a home for your drill press. Allow sufficient room to safely run your machines in any foreseeable operation.
3.Lighting and Outlets: Lighting should be bright enough to eliminate shadow and pre- vent eye strain. Electrical circuits should be dedicated or large enough to handle amper- age requirements. Outlets should be located near each machine so power or extension cords are clear of
|
|
|
|
|
|
|
|
|
|
|
|
G4008/G4009 Drill Press |