Grizzly G0463 owner manual Circuit Requirements, 110V Operation

Page 12

SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G0463 motor draws the following amps under maximum load:

Motor Draw

7 Amps

Circuit Recommendations

We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage with- out consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire hazard—consult a qualified electrician to reduce this risk.

Circuit Breaker....................................... 10 Amps

Plug/Receptacle Type

Included Plug Type

NEMA 5-15

Figure 2. A 5-15 plug and receptacle.

-10-

Electrocution or fire could result if this machine is not grounded correctly or if your electrical configu- ration does not comply with local and state codes. Ensure compliance by checking with a qualified electrician!

This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two-pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Extension Cords

We do not recommend the use of extension cords, if you find it absolutely necessary:

Use at least a 16 gauge cord that does not exceed 50 feet in length!

The extension cord must also contain a ground wire and plug pin.

A qualified electrician MUST size cords over 50 feet long to prevent motor damage.

G0463 Small Mill/Drill

Image 12
Contents Model G0463 Small MILL/DRILL Page Table of Contents Accessories Maintenance Introduction ForewordContact Info Product Dimensions Shipping DimensionsElectrical MotorMain Specifications FeaturesTable Info ConstructionIdentification Safety Safety Instructions for MachineryAlways Lock Mobile Bases if Used Before Operating Machinery Additional Safety for Mill/Drills Circuit Requirements 110V OperationSET UP Set Up SafetyItems Needed for Set Up UnpackingInventory Box 1 Figures 3 QtyItems not shown Clean Up Site ConsiderationsTo install the feet on the mill/drill FeetMounting to Workbench Components and Hardware Needed QtyTo begin the start up and break-in procedure Test Run Spindle Break-inDrill Chuck Removal Tools Needed QtyTo remove the chuck and arbor from the spindle To install the R-8 collet ColletsTo remove the collet Operation Safety Power ControlsOperations Power Shutdown To completely shut the system power OFFSpindle & Headstock Controls To use the rapid downfeedTable Travel Longitudinal FeedCross Feed Setting RPM To determine the needed RPMCutting Speed x 4 /Tool Diameter = RPM Cutting Speeds for High Speed Steel HSS Cutting ToolsAccessories G9324-Boring Head Combo Set G2861-21⁄2 Face MillH2689-R-8 Quick Change Collet Set H5685-4Rotary TableMaintenance ScheduleUnpainted Cast Iron LubricationService About ServiceTroubleshooting Adjusting Gibs To adjust the gibs see FigureReplacing Motor Brushes & Fuse To replace the motor brushesElectrical Components Circuit boardWiring Diagram Parts Breakdown 237 238 240 241 236 242 235 234 Parts List DescriptionPK30M Emergency Stop Switch Warranty and Returns Page Page