Carrier 50XCA06-24 manual Electrical data, Unit Electrical Data

Page 26

Electrical data

UNIT ELECTRICAL DATA

 

UNIT

 

 

VOLTAGE

COMPRESSOR

COMPRESSOR

 

 

V-PH-Hz

 

RANGE

 

NO. 1

 

NO. 2

 

50XCA

 

 

 

 

 

 

 

Min

 

Max

RLA

 

LRA

RLA

 

LRA

 

 

 

 

 

 

 

 

 

 

208/230-3-60

187

 

253

20.5

 

155

 

 

06

 

460-3-60

414

 

506

9.6

 

75

 

 

 

 

575-3-60

518

 

632

7.6

 

54

 

 

 

 

208/230-3-60

187

 

253

22.4

 

149

 

 

08

 

460-3-60

414

 

506

10.6

 

75

 

 

 

 

575-3-60

518

 

632

7.7

 

54

 

 

 

 

208/230-3-60

187

 

253

16.0

 

110

16.0

 

110

 

12

 

460-3-60

414

 

506

7.8

 

52

7.8

 

52

 

 

 

575-3-60

518

 

632

5.7

 

39

5.7

 

39

 

 

 

208/230-3-60

187

 

253

20.5

 

155

20.5

 

155

 

14

 

460-3-60

414

 

506

9.6

 

75

9.6

 

75

 

 

 

575-3-60

518

 

632

7.6

 

54

7.6

 

54

 

 

 

208/230-3-60

187

 

253

23.2

 

164

23.2

 

164

 

16

 

460-3-60

414

 

506

11.2

 

75

11.2

 

75

 

 

 

575-3-60

518

 

632

7.9

 

54

7.9

 

54

 

 

 

208/230-3-60

187

 

253

30.1

 

225

30.1

 

225

 

24

 

460-3-60

414

 

506

16.7

 

114

16.7

 

114

 

 

 

575-3-60

518

 

632

12.2

 

80

12.2

 

80

 

 

LEGEND

 

 

 

 

 

 

 

 

 

FLA

Full Load Amps

 

 

 

 

 

 

 

 

 

LRA

Locked Rotor Amps

 

 

 

 

 

 

 

 

 

NEC

National Electrical Code

 

 

 

 

 

 

 

 

 

RLA

Rated Load Amps

 

 

 

 

 

 

 

 

 

NOTES:

1.In compliance with NEC requirements for multimotor and combination load equipment (NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR circuit breaker. Canadian units may be fuse or circuit breaker.

2.Wire sizing amps are a sum of 125% of the compressor RLA plus 100% of indoor fan motor FLA.

3.Motors are protected against primary single phasing condition.

4.Indoor-fan motors are 3-phase motors of same voltage as unit.

26

Image 26
Contents Features/Benefits Product DataTable of contents Model number nomenclature AHRI* capacity ratingsPhysical data CompressorDimensions 50XCA06-14 Front ViewDimensions 50XCA16,24 Rear ViewSelection procedure 50XCA08 unit example Performance data Gross Cooling CapacitiesGross Cooling Capacities 50XCA12 10 Tons 50XCA14 12 Tons 50XCA16 15 Tons 50XCA024 20 Tons Condenser FAN Performance Condenser FAN Performance 50XCA12 10 Tons ESP in. wg 50XCA14 12 Tons ESP in. wg 50XCA16 15 Tons ESP in. wg 50XCA24 20 Tons ESP in. wg Evaporator FAN Performance Evaporator FAN Performance 50XCA012 10 Tons ESP in. wg Bhp Rpm Bhp Rpm 4500 000 Electrical data Unit Electrical DataFAN Electrical Data Typical wiring schematic GND GNDTo Line Controls Operating sequenceTypical piping and wiring A50-8506Application data LocationSetting condenser fan speed Guide specifications System DescriptionPage Carrier Corporation Syracuse, New York 310