Moffat P12M, P8M operation manual Water Tank Element, Condensation Channel, Door Seal

Page 11

Cleaning

e.Dry the racks thoroughly with a dry cloth and polish with a soft dry cloth.

f.To refit the racks, engage the front and rear upper rack keyholes onto the upper hanger studs.

g.Raise the rack up again slightly until the lower rack keyholes engage onto the lower studs, ensuring that the upper studs remain engaged.

h.Push down on the rack to ensure that it is fully engaged onto the upper and lower hanger studs.

NOTE: Ensure that the rack is securely fitted and that ALL the studs are engaged into the rack key holes.

Water Tank

It is recommended that this procedure is carried out once a week. Frequency of cleaning the element may be increased or decreased depending on the quantity of scale depositing on the element.

a.To remove the water tank, remove the RH side rack as shown previously.

b.Remove the water tank by lifting the tank off its hanger studs. Clean with warm soapy water. Rinse thoroughly and refit.

Water Tank

Hanger Studs

Water Tank Element

a.When the wet element becomes limed / scaled up, remove the water tank and clean as shown previously.

Wet Element

Water

Inlet

Water Level Sensor

b.Refit the water tank and half fill with white vinegar or acetic acid, then fill to the normal level with water. Switch ‘On’ the unit, and turn the Humidity Control to ‘8’. Operate for approximately 30 minutes.

c.When cooled, remove the water tank and clean the element with a damp cloth. Rinse out the water tank and refit to the unit.

Door

a.Wash with warm water and a mild detergent solution using a soft sponge in straight lines up and down the inner and outer surfaces of the door. Rinse with clean, warm water and dry off.

b.Dry the door thoroughly with a soft dry cloth.

c.Clean door glass with a conventional glass cleaner.

Condensation Channel

a.Below the door is a condensation channel for collecting door condensation run-off. This is then fed into a condensation drawer.

Condensation

Channel

Condensation Drawer

b.Empty the condensation drawer on a regular basis and once a week, wipe out the condensation channel and drawer with a damp cloth moistened with warm water and a mild detergent solution.

c.Dry with a soft dry cloth.

Door Seal

Clean the door seal with warm water and a detergent solution using a soft sponge when required.

Should the door seal become dirty, it can be removed for a more thorough cleaning should this be necessary:-

Pull Seal out of locating channel

a.To remove the 1 piece seal, pull seal forward until it pulls out of the location groove around the door.

b.Note the way the seal is fitted to the door, with the lip facing inwards.

c.Check the seal for wear and damage and replace if damaged or worn.

d.The seal may be washed in a sink, taking care not to cut or damage the seal.

e.Dry the seal thoroughly with a soft dry cloth before re-fitting.

f.To refit seal, have lip facing into the centre of door.

g.Press the seal into the locating groove around the door until the seal is properly located.

9

Image 11
Contents P8M / P12M Series Manufactured by Contents List Introduction Safety InformationTray Details SpecificationsPower Ratings Clearances InstallationInstallation Requirements UnpackingMax Inlet Pressure 80psi / 550kPa Water ConnectionOperation Set the Function Control 2 to ‘HOLD’ Set the Function Control 2 to ‘ON’Set Humidity Control 6 to the desired level Side Racks CleaningProofer / Holding Cabinet Cleaning Stainless Steel SurfacesCondensation Channel Water TankWater Tank Element DoorLamp Glass Fault Possible Causes Remedy Fault FindingElectrical Schematic P8M P12M Proofer Holding Cabinets Electrical SchematicDescription Replacement Parts List