Moffat P8M, P12M operation manual Operation

Page 8

Operation

Operation Guide

Turbofan Proofer / Holding Cabinets have been designed to provide simple operation.

This Proofer / Holding Cabinet is intended for use in a commercial kitchen and must only be put to the use for which it was intended, i.e. proofing and holding of food products. To use this Proofer / Holding Cabinet correctly, please read the following sections carefully:-

Proofer / Holding Cabinet Control Panel

1

Control Panel (˚F)

Control Panel (˚C)

2

1

2

3

3

4

4

5

6

Description of Controls

Power ‘On’ Indicator Light

Indicator light illuminates when the ‘Function’ Switch is turned to ‘ON’ or ‘HOLD’.

Function Control

IUnit is ‘Off’.

ON Unit is in Proofing Mode (Power ‘On’ Indicator Light illuminates).

HOLD Unit is in Holding Mode (Power ‘On’ Indicator Light illuminates).

Heating ‘On’ Indicator Light

Indicator light illuminates when ‘Thermostat Heating’ is turned ‘ON’ and the elements are cycling ‘ON’ to maintain set temperature.

Thermostat Control

Controls air temperature in the Proofer / Holding Cabinet.

Temperature Range -

0 - 85°C / 32 - 185°F.

Proofing Range -

20

- 40°C / 65 - 105°F.

Holding Range -

65

- 85°C / 150 - 185°F.

7

5

6

7

Humidity ‘On’ Indicator Light

Indicator light illuminates when ‘Humidity Control’ is turned ‘ON’ and elements are cycling ‘ON’ to maintain the set humidity. (Controls the cabinet humidity in PROOF Mode only).

Humidity Control

Controls humidity level in the proofer / holding cabinet. Controls the cabinet humidity in PROOF Mode only.

1 to 5 Suggested settings for butter based pastries

(Croissants, Danish Pastries etc).

5 to 8 Suggested settings for yeast based breads and doughs.

Thermometer

Indicates the cabinet temperature.

Dual Centigrade and Fahrenheit scale.

6

Image 8
Contents P8M / P12M Series Manufactured by Contents List Safety Information IntroductionTray Details SpecificationsPower Ratings Installation Installation RequirementsUnpacking ClearancesWater Connection Max Inlet Pressure 80psi / 550kPaOperation Set the Function Control 2 to ‘HOLD’ Set the Function Control 2 to ‘ON’Set Humidity Control 6 to the desired level Cleaning Proofer / Holding Cabinet CleaningStainless Steel Surfaces Side RacksWater Tank Water Tank ElementDoor Condensation ChannelLamp Glass Fault Finding Fault Possible Causes RemedyElectrical Schematic Electrical Schematic P8M P12M Proofer Holding CabinetsReplacement Parts List Description