Heath Zenith SH-5311 manual Test and Adjustment, Specifications

Page 4
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the RANGE control to the mid position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

ON-TIMERANGE

ON-TIME RANGE

10 5 1 TEST

 

MIN MAX

MIN MAX

10 5

1 TEST

 

MINUTES

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

180°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is most sensitive to motion across its field of view.

Loosen the clamp screw in theClamp

sensor ball joint and gently Screw

rotate the sensor.

 

 

 

Walk through the coverage

 

 

Ball

 

 

area noting where you are

 

 

 

 

Joint

when the lights turn on (also,

 

 

 

 

 

the LED will flash several times

 

 

 

whenmotionisdetected).Move

 

 

 

the sensor head up, down, or

 

 

 

sideways to change the cover-

Aim Sensor

age area.

Down for Short

AdjusttheRANGEasneeded.

Coverage

RANGE set too high may

 

 

 

increase false triggering.

 

 

 

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you

want the lights to stay on after motion is detected (1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 180°

Electrical Load. . . . Up to 500 Watts Maximum Tungsten.

Power Requirements. . 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Replacement lamp. . . T, 500W (or less) halogen 120

VAC

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

Motion

Motion

 

Sensor

Least Sensitive

Most Sensitive

598-1343-00

Image 4
Contents Operation FeaturesRequirements Installation Wire the Light ControlMode Switching Summary Remove the existing light fixtureMount the Light Control Bulb Installation and Re-lampingMount Horizontally Test and Adjustment SpecificationsTroubleshooting Guide Symptom Possible Cause SolutionTechnical Service No Service Parts Available for this ProductCaracterísticas FuncionamientoRequisitos Conecte el control de luz InstalacionResumen de las modalidades del Interruptor Instale el control de luz Instalación y cambio de bombillaMontelo Horizontalmente Cuidado Para evitar los peligros de incen Dio o quemazónPrenda el cortacircuitos y el interruptor de luz Prueba Y AjusteEvite apuntar el control hacia Guia DE Investigacion DE Averias Modo ManualServicio Técnico No hay piezas de servicio disponibles para este productoCaractéristiques FonctionnementExigences Câblage De La Commande ’Éclairage Résumé du mode de commutationNoir / noir Blanc / blancInstallation et remplacement de ’ampoule Montage De La Commande ’ÉclairageMonter Horizontalement Essais ET Réglages Éviter de pointer l’appareilGuide DE Dépannage Fiche TechniqueCause Possible Service Technique Aucune pièce de rechange n’est disponible pour ce produit598-1343-00 Date of Purchase