TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period be- fore it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.
❒Turn the RANGE control to the mid position, DualBrite® to OFF and the
MAX |
|
|
|
| |
B | O | ON - TIME | DUAL BRITE | ||
| |||||
| O |
|
| ||
| S |
|
| ||
MIN | T |
|
|
| |
TEST 1 5 2 0 | OFF 3 6 | DUSK TO | |||
RANGE | |||||
| MINUTES | HOUR | DAWN |
Bottom of Sensor
Avoid aiming the sensor at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
240°
8 ft.
(2.4 m)
70 ft. 100 ft.
(21 m) (30.5 m) Boosted
Maximum Range | Maximum |
| Coverage Angle |
The detector is less sensitive to motion directly towards it.
MotionMotion
| Sensor |
Least Sensitive | Most Sensitive |
❒ Loosen the clamp screw in the | Clamp |
sensor ball joint and gently | Screw |
rotate the sensor. |
|
❒ Walk through the coverage | Ball |
area noting where you are | Joint |
when the lights turn on. Move |
|
the sensor head up, down, |
|
or sideways to change the | Aim Sensor |
coverage area. | |
❒ Adjust the RANGE as needed. | Down for Short |
RANGE set too high may | Coverage |
increase false triggering. |
|
❒Secure the sensor head’s
aim by tightening the clamp screw. Do not overtighten the
screw.
❒ Set the amount of TIME you want the lights to stay on after
motion is detected (1, 5, or 20 minutes).
❒Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs.,
SPECIFICATIONS
Range | Up to 70 ft. (21 m); 100 ft. |
| (30.5 m) with Range Boost. |
| [varies with surrounding |
| temperature] |
Sensing Angle. . . . | Up to 240° |
Electrical Load. . . . | Up to 500 Watt Maximum |
| Incandescent |
Power Requirements. . 120 VAC, 60 Hz | |
Operating Modes. . . | TEST, AUTO and MANUAL |
| MODE |
Time Delay | 1, 5, 20 minutes |
Replacement lamp. . . T 500W (or less) halogen 120
VAC
DualBrite® Timer. . . 3, 6 hours,
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.