Heath Zenith SL-5311 manual Test and Adjustment, Specifications, Maximum Range, Least Sensitive

Page 3
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period be- fore it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.

Turn the RANGE control to the mid position, DualBrite® to OFF and the ON-TIME control to the TEST position.

MAX

 

 

 

 

B

O

ON - TIME

DUAL BRITE

 

 

O

 

 

 

S

 

 

MIN

T

 

 

 

TEST 1 5 2 0

OFF 3 6

DUSK TO

RANGE

 

MINUTES

HOUR

DAWN

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

240°

8 ft.

(2.4 m)

70 ft. 100 ft.

(21 m) (30.5 m) Boosted

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion directly towards it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the

Clamp

sensor ball joint and gently

Screw

rotate the sensor.

 

Walk through the coverage

Ball

area noting where you are

Joint

when the lights turn on. Move

 

the sensor head up, down,

 

or sideways to change the

Aim Sensor

coverage area.

Adjust the RANGE as needed.

Down for Short

RANGE set too high may

Coverage

increase false triggering.

 

Secure the sensor head’s

aim by tightening the clamp screw. Do not overtighten the

screw.

Set the amount of TIME you want the lights to stay on after

motion is detected (1, 5, or 20 minutes).

Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

SPECIFICATIONS

Range

Up to 70 ft. (21 m); 100 ft.

 

(30.5 m) with Range Boost.

 

[varies with surrounding

 

temperature]

Sensing Angle. . . .

Up to 240°

Electrical Load. . . .

Up to 500 Watt Maximum

 

Incandescent

Power Requirements. . 120 VAC, 60 Hz

Operating Modes. . .

TEST, AUTO and MANUAL

 

MODE

Time Delay

1, 5, 20 minutes

Replacement lamp. . . T 500W (or less) halogen 120

VAC

DualBrite® Timer. . . 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

595-5497-12

Image 3
Contents Operation FeaturesMode Switching Summary DualBrite TimerInstallation Remove the existing light fixtureMount Horizontally Least Sensitive Test and AdjustmentSpecifications Maximum RangeTroubleshooting Guide No Service Parts Available for this ProductTEN Year Limited Warranty Resumen de las modalidades del interruptor FuncionamientoCaracterísticas RequisitosInstalacion Montelo HorizontalmenteCuidado Para evitar los peligros de incendio Quemazón Cobertura Máxima Prueba Y AjusteEspecificaciones Angulo deGarantía Limitada a 10 Años Guia DE Investigacion DE AveriasServicio Técnico No hay piezas de servicio disponibles para este productoMinuterie DualBrite FonctionnementCaractéristiques ExigencesMonter Horizontalement Montage De La Commande D’ÉclairageCâblage De La Commande D’Éclairage Installation et remplacement de l’ampouleLe moins sensible Essais ET RéglagesFiche Technique Angle deService Technique Guide DE DépannageGarantie Limitée DE 10 ANS