Powermatic 60C, 60HH Adjustments, Extension Cords, Installing and Adjusting Knives

Page 14

Three-Phase Test Run

On the three-phaseunit, after wiring has been completed, you should check that the incoming leads have been connected properly:

1.Connect machine to power source and press the start button. Make sure cutterhead is clear of all obstructions! (See page 21 for more detailed instructions on the switch.)

2.The cutterhead should rotate clockwise as viewed from the front of the machine. If the cutterhead rotation is incorrect, press the stop button and disconnect machine from power.

3.Switch any two of the three leads to the motor, then re-connect to power.

Extension Cords

Make sure your extension cord is in good condition. Always use a cord that is heavy enough to carry the current your product will draw; the cord rating must be suitable for the amperage listed on the machine’s motor plate. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.

Use the chart in Figure 15 as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Adjustments

Disconnect machine from power source before making adjustments.

Tools required for adjustments:

8mm & 12mm wrenches 4mm hex wrench

machinist's protractor or adjustable square steel straight edge

Installing and Adjusting Knives

(Straight Cutterhead only)

Refer to Figure 16.

Use care when working with or around sharp knives. Make sure power to the machine has been disconnected.

When installing new knives, remove only one knife at a time. Clean the knife slot and install the new knife. Adjust and snug new knife in cutterhead before proceeding to next knife.

Recommended Gauges (AWG) of Extension Cords

 

 

 

Extension Cord Length *

 

 

 

 

 

 

 

 

 

Amps

25

50

75

100

150

200

feet

feet

feet

feet

feet

feet

 

 

 

 

 

 

 

 

< 5

 

16

16

16

14

12

12

 

 

 

 

 

 

 

 

5 to

8

16

16

14

12

10

NR

 

 

 

 

 

 

 

8 to 12

14

14

12

10

NR

NR

 

 

 

 

 

 

 

 

12 to

15

12

12

10

10

NR

NR

 

 

 

 

 

 

 

 

15 to

20

10

10

10

NR

NR

NR

 

 

 

 

 

 

 

 

21 to

30

10

NR

NR

NR

NR

NR

 

 

 

 

 

 

 

 

*based on limiting the line voltage drop to 5V at 150% of the rated amperes.

NR: Not Recommended.

Figure 15

Figure 16

(straight cutterhead only)

14

Image 14
Contents Powermatic Part No. M-1610084Warranty and Service Warranty PeriodTable of Contents Page Page 60C Introduction Specifications3HP 3PH 230/460V prewired Features and Terminology 60C and 60HH Jointers Contents of the Shipping Container UnpackingAssembling Jointer to Stand AssemblyTools required for assembly Cutterhead GuardRemoving Guard Installing Drive BeltAligning Pulleys Installing Dust Chute Installing Belt Guard and Door Installing Switch Arm Hose and clamp not providedElectrical Connections Installing Fence HandwheelKnife Gauge Assembly model 60C only Storing the Push BlocksGrounding Instructions Extension Cords AdjustmentsInstalling and Adjusting Knives Straight cutterhead onlyStraight cutterhead only Replacing and Rotating Knife Inserts Helical Cutterhead OnlyLeveling Tables If table will still not line upRapid Adjust Adjusting Depth of CutSetting Outfeed Table Fine AdjustFence Movement Examples of incorrect settingsSpring Cutting Degree stop Fence StopsSee Figure Degree forward stopOperating Controls Start/StopJointing Short or Thin Work Hand PlacementBasic Jointer Operation Direction of GrainBeveling Jointing Warped SurfacesEdge Jointing Skewing Shear Cutting Taper CutsMaintenance RabbetingCutterhead Maintenance Sharpening Knives model 60C onlyTable Removal Probable Cause Remedy Troubleshooting Mechanical and Electrical ProblemsTrouble Trouble Probable Cause Remedy Helical cutterhead Rotate nicked Troubleshooting Operating ProblemsStraight cutterhead Replace nicked Index No. Part No Description Size Qty Replacement PartsParts List Base Assembly 60C and 60HH 6296044 Base Assembly 60C and 60HH Parts List Fence Assembly 60C and 60HH Fence Assembly 60C and 60HH Parts List Straight Cutterhead Assembly 60C only Parts List Helical Cutterhead Assembly 60HH only Parts List Stand Assembly 60C and 60HH PM2000-105 Stand Assembly 60C and 60HH Electrical Connections Single Phase, 230 Volt Electrical Connections 3 Phase, 230 Volt Electrical Connections 3 Phase, 460 Volt New Sanford Rd LaVergne, TN Phone