Powermatic 1285 Troubleshooting Mechanical and Electrical Problems, Trouble Probable Cause Remedy

Page 25

Trouble

Probable Cause

Remedy

 

 

 

Uneven knife marks

Knives/inserts are knicked, or out of

Replace knicked knives/inserts; align

knives properly with knife-setting gauge

on workpiece.

alignment.

(straight cutterhead only).

 

 

 

 

 

Troubleshooting – Mechanical and Electrical Problems

Trouble

Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.

Probable Cause

Remedy

 

 

No incoming power.

Verify unit is connected to power, and

on-switch is pushed in completely.

 

 

 

 

When jointer overloads on the circuit

 

breaker built into the motor starter, it

 

takes time for the machine to cool

Overload automatic reset has not

down before restart. Allow unit to

reset.

adequately cool before attempting

 

restart. If problem persists, check

 

amp setting on the motor starter

 

inside the electrical enclosure.

 

 

 

One cause of overloading trips which

 

are not electrical in nature is too

 

heavy a cut. The solution is to take a

 

lighter cut. If too deep a cut is not the

 

problem, then check the amp setting

Jointer frequently trips.

on the overload relay. Match the full

 

load amps on the motor as noted on

 

the motor plate. If amp setting is

 

correct then there is probably a loose

 

electrical lead. Check amp setting on

 

motor starter.

 

 

 

Verify that jointer is on a circuit of

Building circuit breaker trips or fuse

correct size. If circuit size is correct,

there is probably a loose electrical

blows.

lead. Check amp setting on motor

 

 

starter.

 

 

 

If you have access to a voltmeter, you

 

can separate a starter failure from a

 

motor failure by first, verifying

 

incoming voltage at 220+/-20 and

 

second, checking the voltage

Motor starter failure.

between starter and motor at 220+/-

20. If incoming voltage is incorrect,

 

 

you have a power supply problem. If

 

voltage between starter and motor is

 

incorrect, you have a starter problem.

 

If voltage between starter and motor

 

is correct, you have a motor problem.

 

 

 

Clean motor of dust or debris to allow

Motor overheated.

proper air circulation. Allow motor to

 

cool down before restarting.

 

 

25

Image 25
Contents Part No. M-0460216 JointerMore Information WMH Tool Group Warranty Warranty and ServiceTable of Contents Page Figure a Page 90, 45 right, 45 left Introduction SpecificationsUnpacking Contents of the Shipping ContainerFence Installation AssemblyTools need for assembly Grounding Instructions Switch ArmDust Hood Extension cords Voltage ConversionSetting Outfeed Table Height AdjustmentsDrive Belt Tension Page Replacing and Setting Knives Straight Cutterhead Setting Infeed Table Height Depth of CutPage Replacing Knife Inserts Helical Cutterhead To check and adjust the 90-degree stop Fence AdjustmentsTo tilt fence forward To tilt fence backwardOperating Controls To check and adjust the 45-degree stopOperation Cutter Guard TensionEdge Jointing Hand PlacementSurfacing RabbetingJointing Short or Thin Work Jointing Warped SurfacesDirection of Grain BevelingLubrication MaintenanceCutterhead Repairs Knife Inserts Helical Cutterhead Whetting Knives Straight Cutterhead Trouble Troubleshooting Operating ProblemsProbable Cause Remedy Trouble Probable Cause Remedy Troubleshooting Mechanical and Electrical ProblemsIf electric motor is suspect, you have Replacement Parts Optional AccessoriesIndex No. Part No Description Size Qty Parts List Stand AssemblyStand Assembly Parts List Table Assembly Table Assembly Parts List Motor Pulley Assembly Motor Pulley Assembly Parts List Cutterhead Guard Assembly Cutterhead Guard Assembly PJ1285-KSGA Parts List Straight Cutterhead AssemblyStraight Cutterhead Assembly Parts List Helical Cutterhead Assembly Helical Cutterhead Assembly Parts List Fence Assembly Fence Assembly Electrical Connections 1 Phase Electrical Connections 3 Phase WMH Tool Group