Bryant 575B, 575C, 541A dimensions Rla Lra, MCA Mocp Option

Page 10

Duplex 575C120, 541A180 with 524A-H240 or 524A-H300

In order to properly connect two heat pump condensing units to a single 524A-H packaged air handler, it is necessary to add field-supplied Fan Coil Relay Board(s), P/N 33ZCRLYBRD. Relay board(s) no. 1 and no. 2 should be installed in the control box of condensing unit.

IMPORTANT: The common (COM) terminals from the fan coil relay board(s) must be connected to the ‘C’ terminal in condensing unit ‘A’.

Route thermostat cable or equivalent single leads of no. 18 AWG (American Wire Gage) colored wire from sub- base terminals through conduit in unit to low-voltage con- nections as shown on unit wiring diagram and Fig. 12 and 13.

NOTE: For wire runs up to 50 ft, use no. 18 AWG insulated wire (35 C minimum). For 51 to 75 ft, use no. 16 AWG insulated wire (35 C minimum). For over 75 ft, use no. 14 AWG insulated wire (35 C minimum). All wire larger than no. 18 AWG cannot be directly connected to the thermostat and will require a junc- tion box and a splice at the thermostat.

Fig. 8 — Wiring Diagram — 575C090,120 —

Control Transformer

Table 7 — Electrical Data

 

 

 

FACTORY-

NOMINAL VOLTAGE

VOLTAGE RANGE*

COMPRESSOR

FAN MOTORS

POWER SUPPLY

UNIT

INSTALLED

 

 

 

 

 

 

 

(V-Ph-Hz)

Min

Max

RLA

LRA

FLA

MCA

MOCP

 

 

 

OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-3-60

187

253

18.9

146

5.1

28.7

45

575B

072

NONE

460-3-60

414

506

9.5

73

2.6

14.5

20

 

 

 

 

575-3-60

517

633

7.6

58

1.2

10.7

15

 

 

 

NONE OR DISCONNECT

208/230-3-60

187

254

29.0

190

1.5

39.0

60

 

 

090

CONVENIENCE OUTLET

43.8

60

 

 

 

 

 

 

 

 

 

 

NONE OR DISCONNECT

460-3-60

418

506

15.0

95

0.7

19.8

30

 

 

 

 

 

 

CONVENIENCE OUTLET

21.9

30

 

 

 

 

 

 

 

 

 

575C

 

NONE OR DISCONNECT

208/230-3-60

187

254

34.0

225

1.5

45.0

60

 

CONVENIENCE OUTLET

50.0

70

 

 

 

 

 

 

 

 

 

 

 

120

NONE OR DISCONNECT

460-3-60

418

506

17.0

114

0.7

23.0

30

 

 

CONVENIENCE OUTLET

25.0

30

 

 

 

 

 

 

 

 

 

 

 

 

NONE OR DISCONNECT

575-3-60

523

632

14.0

80

0.7

18.0

25

 

 

 

CONVENIENCE OUTLET

20.0

25

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-3-60

187

253

63.6

266

4.3

87.5

125

541A

180

NONE

460-3-60

414

528

29.3

120

2.3

40.7

60

 

 

 

 

575-3-60

518

660

23.8

96

1.8

33.0

50

LEGEND

FLA — Full Load Amps

LRA — Locked Rotor Amps

MCA — Minimum Circuit Amps

MOCP — Maximum Overcurrent Protection

NEC — National Electrical Code

RLA — Rated Load Amps

*Units are suitable for use on electrical systems where voltage supplied to the unit terminals is not below or above the listed limits.

NOTES:

1.The MCA and MOCP values are calculated in accordance with the NEC, Article 440.

2.Motor RLA and LRA values are established in accordance with Underwriters’ Laboratories (UL), Standard 1995.

3.The 575-v units are UL, Canada-listed only.

4.Convenience outlet is available as either a factory-installed option or a field-installed accessory and is 115-v, 1 ph, 60 Hz.

10

Image 10
Contents Installation Complete PRE-INSTALLATION Checks ContentsSafety Considerations GeneralLocate Unit Mount Unit575C090,120 Unit Dimensions 180 803 158 Weight lb kgUnit 244Component Locations 541A180 Shown Compressor Physical Data 575B072, 575C090,120 and 541A180 UnitsRefrigerant Outdoor FansIII. Complete Refrigerant Piping Connections Minimum Outdoor Air Operating Temperature Provide Safety ReliefVapor Line Piping Procedure Refrigerant Specialties Part NumbersIV. Complete Electrical Connections RLA LRA MCA Mocp OptionSEN LP/HPTstat IFC EquipGND IFMGND HTR → Recommended Process for Checking for Leaks PRE-START-UPPreliminary Checks II. Preliminary ChargeIV. Accumulator III. Advanced Scroll Temperature Protection AstpIII. Liquid Line Solenoid START-UPPreliminary OIL Charge 541A VII. Adjust Refrigerant ChargeIV. Compressor Lockout Device VI. Start UnitSequence of Operation Duplex 575C120 Units with 524A-H240 See Fig III A180 Units HeatingIV. Duplex Units Duplex 575C120 and 541A180 Units With 524A-H300 See FigRestart Service Compressor RemovalVI. Causes of Complete Unit Shutdown VI. Crankcase Heater IV A180 Cooling Mode Operation See Fig541A180 Heating Mode Operation See Fig VII. Outdoor Unit Fans575C090,120 Heating Mode Size 090 Shown Cleaning Standard Coils IX. Coil Cleaning and MaintenanceCleaning and Maintaining E-Coated Coils Coil Cleaning Typical Pivot and Support Top CoverTroubleshooting Chart Heating Cycle Thermostatic Expansion Valve CCH TXVControls Preliminary InformationII. PRE-START-UP Outdoor Unit Indoor UnitIII. START-UP Cooling Heating

541A, 575B, 575C specifications

The Bryant 575B, 541A, and 575C heating and cooling units are part of the renowned Bryant lineup, designed to provide efficient and reliable climate control solutions for residential and commercial spaces. These models are particularly celebrated for their impressive performance, innovative technologies, and user-friendly operations.

Starting with the Bryant 575B, this model is a high-efficiency air conditioner that boasts a SEER rating of up to 20.5. It utilizes a variable-speed compressor that adjusts its output based on the temperature needs of the home, leading to enhanced energy savings and consistent indoor comfort. The 575B is equipped with a steel cabinet that resists corrosion and damage while also minimizing noise levels during operation. Additionally, its environmentally friendly R-410A refrigerant helps to reduce the system's ecological footprint.

Moving on to the Bryant 541A, this unit is a formidable gas furnace known for its exceptional heating capabilities. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 97.5%, the 541A efficiently transforms fuel into heat, ensuring lower energy bills during cold months. It incorporates advanced technologies such as a two-stage gas valve and a variable-speed blower motor, allowing it to respond dynamically to the heating demands of the home. The insulated cabinet construction further enhances energy efficiency by preventing heat loss and increasing comfort.

Lastly, the Bryant 575C model is a versatile heat pump that offers both heating and cooling functionalities, ideal for regions with moderate heating and cooling needs. It features a SEER rating of up to 20 and an HSPF (Heating Season Performance Factor) rating of up to 10.5, making it an energy-efficient choice year-round. The 575C comes with a streamlined design that integrates a variable-speed compressor, which helps maintain precise temperatures and minimizes energy consumption. Additionally, its quiet operation is enhanced by sound insulation, providing a serene indoor environment.

All three models are designed with durability in mind, featuring robust construction materials that withstand the elements. They can be easily integrated with smart thermostats, providing homeowners with greater control over their energy use. With exceptional efficiency ratings, durable designs, and advanced features, the Bryant 575B, 541A, and 575C represent a perfect blend of comfort and cutting-edge technology. Whether for heating or cooling, these units deliver outstanding performance to meet the needs of today's energy-conscious consumers.