Bryant 575B, 575C, 541A dimensions Iii. Start-Up, Cooling Heating

Page 28

III. START-UP

CHECK INDOOR FAN SPEED AND RECORD. _______________

CHECK OUTDOOR FAN SPEED AND RECORD. ________________

AFTER AT LEAST 10 MINUTES RUNNING TIME, RECORD THE FOLLOWING MEASUREMENTS:

 

 

COOLING

HEATING

OIL PRESSURE

 

__________________

__________________

SUCTION PRESSURE

 

__________________

__________________

SUCTION LINE TEMP

 

__________________

__________________

DISCHARGE PRESSURE

 

__________________

__________________

DISCHARGE LINE TEMP

 

__________________

__________________

ENTERING OUTDOOR AIR

 

__________________

__________________

LEAVING OUTDOOR AIR TEMP

 

__________________

__________________

INDOOR ENTERING-AIR DB (dry bulb) TEMP

__________________

__________________

INDOOR ENTERING-AIR WB (wet bulb) TEMP

__________________

__________________

INDOOR LEAVING-AIR DB TEMP

 

__________________

__________________

INDOOR LEAVING-AIR WB TEMP

 

__________________

__________________

COMPRESSOR AMPS (L1/L2/L3)

_______ / _______

/ _______

_______ / _______ / _______

CHECK THE COMPRESSOR OIL LEVEL SIGHT GLASSES; ARE THE SIGHT GLASSES SHOWING OIL LEVEL IN VIEW? (Y/N)

NOTES:

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

______________________________________________________________________________________________________________

CUT ALONG DOTTED LINE

CUT ALONG DOTTED LINE

Copyright 2004 Bryant Heating & Cooling Systems

Printed in U.S.A.

10-05A

CL-2

CATALOG NO. 5357-506

Image 28
Contents Contents Safety ConsiderationsInstallation Complete PRE-INSTALLATION Checks GeneralLocate Unit Mount Unit575C090,120 Unit Dimensions Weight lb kg Unit180 803 158 244Component Locations 541A180 Shown Physical Data 575B072, 575C090,120 and 541A180 Units RefrigerantCompressor Outdoor FansIII. Complete Refrigerant Piping Connections Provide Safety Relief Vapor Line Piping ProcedureMinimum Outdoor Air Operating Temperature Refrigerant Specialties Part NumbersIV. Complete Electrical Connections RLA LRA MCA Mocp OptionSEN LP/HPTstat Equip GNDIFC IFMGND HTR PRE-START-UP Preliminary Checks→ Recommended Process for Checking for Leaks II. Preliminary ChargeIII. Advanced Scroll Temperature Protection Astp III. Liquid Line SolenoidIV. Accumulator START-UPVII. Adjust Refrigerant Charge IV. Compressor Lockout DevicePreliminary OIL Charge 541A VI. Start UnitSequence of Operation III A180 Units Heating IV. Duplex UnitsDuplex 575C120 Units with 524A-H240 See Fig Duplex 575C120 and 541A180 Units With 524A-H300 See FigRestart Service Compressor RemovalVI. Causes of Complete Unit Shutdown IV A180 Cooling Mode Operation See Fig 541A180 Heating Mode Operation See FigVI. Crankcase Heater VII. Outdoor Unit Fans575C090,120 Heating Mode Size 090 Shown Cleaning Standard Coils IX. Coil Cleaning and MaintenanceCleaning and Maintaining E-Coated Coils Coil Cleaning Typical Pivot and Support Top CoverTroubleshooting Chart Heating Cycle Thermostatic Expansion Valve CCH TXVPreliminary Information II. PRE-START-UP Outdoor UnitControls Indoor UnitIII. START-UP Cooling Heating

541A, 575B, 575C specifications

The Bryant 575B, 541A, and 575C heating and cooling units are part of the renowned Bryant lineup, designed to provide efficient and reliable climate control solutions for residential and commercial spaces. These models are particularly celebrated for their impressive performance, innovative technologies, and user-friendly operations.

Starting with the Bryant 575B, this model is a high-efficiency air conditioner that boasts a SEER rating of up to 20.5. It utilizes a variable-speed compressor that adjusts its output based on the temperature needs of the home, leading to enhanced energy savings and consistent indoor comfort. The 575B is equipped with a steel cabinet that resists corrosion and damage while also minimizing noise levels during operation. Additionally, its environmentally friendly R-410A refrigerant helps to reduce the system's ecological footprint.

Moving on to the Bryant 541A, this unit is a formidable gas furnace known for its exceptional heating capabilities. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 97.5%, the 541A efficiently transforms fuel into heat, ensuring lower energy bills during cold months. It incorporates advanced technologies such as a two-stage gas valve and a variable-speed blower motor, allowing it to respond dynamically to the heating demands of the home. The insulated cabinet construction further enhances energy efficiency by preventing heat loss and increasing comfort.

Lastly, the Bryant 575C model is a versatile heat pump that offers both heating and cooling functionalities, ideal for regions with moderate heating and cooling needs. It features a SEER rating of up to 20 and an HSPF (Heating Season Performance Factor) rating of up to 10.5, making it an energy-efficient choice year-round. The 575C comes with a streamlined design that integrates a variable-speed compressor, which helps maintain precise temperatures and minimizes energy consumption. Additionally, its quiet operation is enhanced by sound insulation, providing a serene indoor environment.

All three models are designed with durability in mind, featuring robust construction materials that withstand the elements. They can be easily integrated with smart thermostats, providing homeowners with greater control over their energy use. With exceptional efficiency ratings, durable designs, and advanced features, the Bryant 575B, 541A, and 575C represent a perfect blend of comfort and cutting-edge technology. Whether for heating or cooling, these units deliver outstanding performance to meet the needs of today's energy-conscious consumers.