Bryant installation instructions Fan Performance 548D102 Horizontal Discharge Units

Page 26

Table 12 — Fan Performance 548D102 — Horizontal Discharge Units

STANDARD MOTOR (BELT DRIVE)

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

2550

501

0.57

577

587

0.79

747

659

1.05

956

722

1.29

1156

780

1.55

1378

 

2660

507

0.59

592

592

0.82

771

663

1.08

981

727

1.32

1182

784

1.58

1404

 

2700

520

0.65

638

604

0.89

827

672

1.14

1031

737

1.40

1250

793

1.66

1473

 

2800

533

0.71

684

615

0.95

875

683

1.20

1081

747

1.49

1327

802

1.75

1552

 

2900

546

0.77

731

626

1.02

932

693

1.27

1140

756

1.57

1396

813

1.84

1630

 

3000

559

0.83

779

637

1.09

989

704

1.35

1207

765

1.66

1473

823

1.94

1718

 

3100

572

0.90

835

648

1.17

1056

715

1.43

1275

775

1.74

1543

832

2.05

1814

 

3200

585

0.96

883

660

1.24

1114

727

1.52

1353

785

1.83

1321

841

2.15

1901

 

3300

598

1.03

940

671

1.32

1182

739

1.62

1439

795

1.91

1691

851

2.26

1997

 

3400

610

1.10

998

682

1.41

1258

750

1.72

1526

806

2.01

1779

860

2.36

2084

 

3500

623

1.17

1056

694

1.50

1335

761

1.82

1613

817

2.11

1866

870

2.47

2180

 

3600

636

1.25

1123

707

1.60

1422

772

1.93

1709

828

2.23

1971

880

2.57

2266

 

3700

649

1.33

1190

720

1.71

1517

783

2.03

1796

840

2.35

2076

890

2.69

2369

 

3750

655

1.37

1224

727

1.77

1569

789

2.09

1849

846

2.42

2136

896

2.75

2420

 

3800

661

1.41

1258

733

1.82

1613

795

2.15

1901

852

2.48

2188

901

2.80

2462

 

3900

674

1.49

1327

746

1.93

1709

806

2.26

1997

863

2.61

2300

912

2.93

2571

 

4000

687

1.57

1396

759

2.05

1814

817

2.38

2102

874

2.75

2420

923

3.08

2694

 

4100

699

1.60

1473

772

2.17

1919

828

2.50

2206

885

2.88

2529

935

3.23

2815

 

4200

712

1.75

1552

785

2.30

2032

840

2.64

2326

897

3.03

2653

947

3.39

2940

 

4250

719

1.80

1595

792

2.37

2093

846

2.71

2386

903

3.10

2710

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDARD MOTOR (BELT DRIVE) (cont)

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

2550

836

1.83

1621

887

2.13

1884

931

2.45

2162

964

2.77

2436

986

3.11

2718

 

2660

839

1.87

1656

891

2.17

1919

936

2.49

2197

973

2.82

2479

999

3.16

2759

 

2700

846

1.95

1726

898

2.26

1997

946

2.58

2275

987

2.91

2554

1019

3.26

2839

 

2800

855

2.04

1805

906

2.35

2076

954

2.67

2352

997

3.01

2637

1034

3.36

2917

 

2900

863

2.13

1884

913

2.44

2154

961

2.77

2436

1006

3.12

2727

 

3000

872

2.22

1962

921

2.54

2240

969

2.88

2529

1014

3.22

2807

 

3100

882

2.33

2058

930

2.65

2335

976

2.99

2620

1021

3.34

2902

 

3200

892

2.45

2162

939

2.76

2428

984

3.10

2710

 

3300

902

2.57

2266

948

2.88

2529

993

3.21

2799

 

3400

912

2.69

2369

958

3.01

2637

1002

3.34

2902

 

3500

921

2.82

2479

968

3.15

2751

 

3600

930

2.95

2587

978

3.29

2862

 

3700

940

3.07

2686

 

3750

945

3.14

2743

 

3800

949

3.20

2781

 

3900

959

3.33

2894

 

4000

 

4100

 

4200

 

4250

 

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

NOTES:

1.Boldface indicates field-supplied drive is required. (See Note 6.)

2. indicates field-supplied motor and drive are required.

3.Maximum usable watts input is 2120 and maximum continuous bhp is 2.40. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with

confidence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.

4.Values include losses for filters, unit casing, and wet coils.

5.Use of a field-supplied motor may affect wire sizing. Contact your representative to verify.

6.Standard motor drive range: 685 to 935 rpm. All other rpms require field-supplied drive.

7.Interpolation is permissible. Do not extrapolate.

26

Image 26
Contents Installation ContentsSafety Considerations Provide Unit SupportRoof Curb Details IV. RIG and Place Unit III. Install Condensate Drain Line and External TrapII. Field Fabricate Ductwork PositioningUnit MAX Dimensions Weight Base Unit Dimensions Physical Data Unit Size 548D575-3-60 Field Power SupplyMake Electrical Connections 460-3-60Type Electrical Data Units Without Electrical Convenience OutletSIZE† RLA LRA FLA81/2 Tons Electrical Data Units With Electrical Convenience OutletMin FLA VI. Adjust FACTORY-INSTALLED Options Stage Unit Voltage208/230 460 575 Durablade Economizer Installation Durablade Economizer Damper Minimum Position Setting EconoMi$er Component Locations Rear EconoMi$er Flange Installation EconoMi$er Wiring Wiring Diagram for Power Exhaust System Changeover Set Points Default Potentiometer SettingsVII. Adjust INDOOR-FAN Speed Typical Belt-Drive Motor Mounting for Size Unit INDOOR-FAN Maximum Acceptable Fan Rpm at Motor Pulley SettingsIndoor-Fan Motor Performance Continuous BHPFan Performance 548D090 Vertical Discharge Units Standard Motor Belt DriveFan Performance 548D102 Vertical Discharge Units Fan Performance 548D120 Vertical Discharge Units 548D120 10 Tons Standard and Alternate Motors Belt DriveFan Performance 548D090 Horizontal Discharge Units Fan Performance 548D102 Horizontal Discharge Units Fan Performance 548D120 Horizontal Discharge Units Standard and Alternate Motors Belt DrivePRE-START-UP Internal WiringVI. Refrigerant Service Ports START-UP Unit PreparationCooling IX. Adjust GAS InputXII. Safety Relief XI. HeatingDefrost Service CleaningCooling, Units With EconoMi$er Indoor CoilII. Lubrication IV. Economizer Adjustment Refrigerant ChargeCooling Charging Chart 548D102 Problem Cause Remedy TroubleshootingHeating and Cooling Troubleshooting IFO Durablade Economizer TroubleshootingIFC OATTo minimum position Damper does not openEconoMi$er operation limited Damper positionTypical Wiring Diagram Must Voltage Page Preliminary Information START-UP ChecklistTemperatures III. START-UP Electrical

548D specifications

The Bryant 548D heat pump stands out in the HVAC market for its robust performance, energy efficiency, and advanced technology. Known for its reliability, this particular model is designed to provide optimal heating and cooling for both residential and light commercial applications.

One of the standout features of the Bryant 548D is its variable-speed compressor, which allows for precise temperature control and enhances comfort levels in any environment. This technology enables the 548D to operate efficiently at different speeds, adjusting its output based on the heating or cooling demand. As a result, homeowners can enjoy consistent temperature regulation without the wide fluctuations typical of single-stage systems.

In addition to the variable-speed compressor, the Bryant 548D utilizes advanced refrigerant technology. It employs the environmentally friendly Puron refrigerant, which not only improves the unit's efficiency but also reduces its carbon footprint. This makes the 548D a sustainable choice for those looking to minimize their environmental impact while still enjoying superior heating and cooling performance.

Another key characteristic of the Bryant 548D is its impressive energy efficiency rating, often exceeding the minimum requirements set by the Department of Energy. With a high Seasonal Energy Efficiency Ratio (SEER) for cooling in warmer months and an excellent Heating Seasonal Performance Factor (HSPF), the 548D minimizes energy consumption while maximizing comfort.

The 548D also features Quiet Operation technology, ensuring that the system runs quietly in the background without disrupting daily activities. This is particularly beneficial for light commercial spaces or homes where noise can be a concern. The sleek design and compact size make the unit easy to install in various settings without occupying excessive space.

Furthermore, Bryant incorporates advanced smart technology within the 548D model. The system can be integrated with smart thermostats, allowing users to monitor and control their heating and cooling settings remotely. This feature not only enhances convenience but also enables homeowners to program their systems for maximum efficiency.

In conclusion, the Bryant 548D heat pump is an exceptional choice for those seeking a reliable, efficient, and technologically advanced heating and cooling solution. Its combination of variable-speed compression, eco-friendly refrigerant, high energy efficiency, and quiet operation positions it well in the competitive HVAC market, making it a top choice for both residential and light commercial applications. By investing in the Bryant 548D, consumers can enjoy superior comfort and lower energy bills year-round.