SAFETY INFORMATION

INSTALLER INFORMATION

SAFETY INFORMATION

GENERAL INFORMATION WARNING:

The information listed below must be followed during the installation,service,and operation of this unit.Unqualified individuals should not attempt to interpret these instructions or install this equipment.Failure to follow safety recommendations could result in possible damage to the equipment, serious personal injury or death.

The installer must comply with all local codes and regulations which govern the installation of this type of equipment. Local codes and regulations take precedence over any recommendations contained in these instructions. Consult local building codes and the National Electrical Code (ANSI CI) for special installation requirements.

This equipment contains liquid and gaseous refrigerant under high pressure.Installation or servicing should only be performed by qualified trained personnel thoroughly familiar with this type equipment.

All electrical wiring must be completed in accordance with local, state and national codes and regulations and with the National Electric Code (ANSI/NFPA 70) or in Canada the Canadian Electric Code Part 1 CSA C.22.1.

Install this unit only in a location and position as specifi ed on page 4.This unit is designed only for outdoor installations and should be located with consideration of minimizing the length of the supply and return ducts. Consideration should also be given to the accessibility of fuel, electric power, service access, noise, and shade.

Follow all precautions in the literature, on tags, and on labels provided with the equipment. Read and thoroughly understand the instructions provided with the equipment prior to performing the installation and operational checkout of the equipment.

GENERAL INFORMATION

Single packaged heat pumps are ready for easy and immediate installation and can be readily connected into the high static duct system of a home.This unit is completely assembled, wired, and run tested at the factory. This heat pump is designed for outdoor installation only. The only connections needed for installation are the supply and return ducts, the line voltage, and thermostat wiring.Use of components other than those specifi ed may invalidate ARI Certifi cation, Code Agency Listing, and limited warranty on the air conditioner.

Before You Install this Unit

The cooling load of the area to be conditioned must be calculated and a system of the proper capacity selected. It is recommended that the area to be conditioned be completely insulated and vapor sealed.

Check the electrical supply and verify the power supply is adequate for unit operation. If there is any question concerning the power supply, contact the local power company.

All units are securely packed at the time of shipment and upon arrival should be carefully

inspected for damage prior to installing the equipment at the job site. Verify coil fi ns are straight. If necessary, comb fi ns to remove

fl attened or bent fi ns. Claims for damage (apparent or concealed) should be fi led immediately with the carrier.

Please consult your dealer for maintenance information and availability of maintenance contracts. Please read all instructions before installing the unit.

Locating the Heat Pump

Survey the job site to determine the best location for mounting the outdoor unit.

Choose an appropriate location that minimizes the length of the supply and return air ducts.

Overhead obstructions, poorly ventilated areas, and areas subject to accumulation of debris should be avoided.

Suffi cient clearance for unobstructed airfl ow through the outdoor coil must be maintained in order to achieve rated performance. See Figure 3 (page 6) for minimum clearances to obstructions.

Consideration should also be given to availability of electric power, service access, noise, and shade.

4

Image 4
Contents DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCEQ5RF SERIES Single Package Heat Pump - 2 Stage, R-410AINSTALLER INFORMATION USER INFORMATIONRefrigerant Charging Charts for IMPORTANT SAFETY INFORMATIONUSER INFORMATION ABOUT THE HEAT PUMPOperating Instructions Figure 1. Digital ThermostatINSTALLER INFORMATION SAFETY INFORMATIONBefore You Install this Unit GENERAL INFORMATIONFigure 2. Drain Trap HEAT PUMP INSTALLATION Air Duct SystemCondensate Drainage ElbowInstalling Return & Supply Air Fittings Locating & Installing the Return Air AssemblyMake sure the filter is readily accessible Figure 3. Minimum Unit ClearancesFigure 6. Return Air Box Locating & Installing the Supply DampersFigure 7. Supply Damper Pre-ElectricalChecklist Figure 8. Power EntryELECTRICAL CONNECTIONS Line VoltageOvercurrent Protection 2-SpeedOutdoor Fan Motor Select ModelsBlower Speed Ambient Sensor MountingDemand Defrost Control JumperMinimum Time TerminateAccessory AccessoryINDOOR THERMOSTAT SUB-BASESTARTUP & ADJUSTMENTS Pre-StartChecklist Start-UpProcedureAnti Short Cycle Timer Test Forced Defrost Mode Field TestUNIT MAINTENANCE Adjustment of Refrigerant ChargeCharging an R-410AUnit in Heating Mode Refrigerant Charging Charts for Figure 11. Charging Chart for 2 ton UnitsFigure 12. Charging Chart for 3 ton Units Q5RF-X24KCHARGING CHARTRefrigerant Charging Charts for Figure 13. Charging Chart for 4 ton UnitsFigure 14. Charging Chart for 5 ton Units Q5RF-X48KCHARGING CHARTShaded boxes indicate flooded conditions Q5RF-X48K Q5RF-X60KKWIRING DIAGRAM 60HZ/SINGLE PHASE¢711065«¤ 208/230VWIRING DIAGRAM 60HZ/SINGLE PHASE¢711066#¤ 208/230VCOMPONENT FUNCTIONS Low Pressure Switch High Pressure Switch¢709158D¤ Model Q5RF