Acnodes Q5RF SERIES Wiring Diagram, ¢711065«¤, 208/230V, 60HZ/SINGLE PHASE, TON AND 3 TON

Page 18
WIRING DIAGRAM

18

Figure 15. Q5RF/PPH2RF Series Wiring Diagram - 2 & 3 Ton Units

WIRING DIAGRAM

Q5RF/PPH2RF SERIES SMALL PACKAGE H/P W/DEMAND DEFROST

208/230V

60HZ/SINGLE PHASE

2 TON AND 3 TON

 

 

 

 

 

 

 

 

1. Couper le courant avant de faire letretine.

 

NOTES:

 

 

 

 

 

 

 

 

 

2. Employez uniquement des conducteurs en cuiver.

1. Disconnect all power before servicing.

 

 

 

SEE TABLE FOR FACTORY

 

3. Ne convient pas aux installations de plus de 150V a la terre.

2. For supply connections use copper conductors only.

 

SET BLOWER WIRING

 

 

 

 

 

 

 

 

3. Not sutiable on systems that exceed 150V to ground.

HIGH SPEED

BLACK

 

 

T1

BLOWER

 

 

4. For replacement wires use conductors suitable for 105°C.

BLOWER RELAY

 

RED

 

MOTOR

GREEN / YELLOW

 

5. Unit requires a two stage cooling/heating thermostat

(24V)

 

 

T2

G

 

 

 

ORANGE

 

T3

N

 

 

which uses “G” to call for blower.

 

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

GREY

 

 

T4

L

 

 

9

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

TO “G” ON

 

BLOWER

 

 

T5

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T-STAT

 

RELAY

 

 

 

 

 

GREY

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRASFORMER

BLACK

 

 

 

 

 

 

 

 

BLACK

 

 

YELLOW

6

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

240V

COM

 

 

RED

 

 

 

 

YELLOW

BLUE

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

ORANGE

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BROWN

1

 

24V

BLACK

 

 

 

 

 

 

 

 

 

 

TO “W3” ON

 

 

 

 

 

 

 

L2

L1

 

 

 

 

T-STAT

 

 

RED AMBIENT THERMISTOR

 

 

 

 

BLACK

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACTOR

 

 

 

LOW PRESSURE

 

 

 

 

 

 

 

 

 

T2

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COND

FAN

 

 

 

 

 

(SELECT MODELS ONLY)

 

 

 

AMBIENT

 

M

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE

 

AMBG

 

 

PRESS

 

 

 

YELLOW

 

YELLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEMAND

 

 

 

 

 

 

 

 

 

3 AMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL

DEFROST CONTROL

 

 

 

 

 

 

 

YELLOW

COIL THERMISTOR

 

 

BOARD

 

 

 

 

 

 

 

 

COILG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W2 W2

SW

 

 

 

YELLOW / BLACK

 

YELLOW / BLACK

 

TEST

 

R C

 

 

 

 

 

 

 

 

 

 

L

Y

O IN OUT

REV

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

BLACK

 

 

 

HIGH PRESSURE

 

 

 

 

 

 

 

 

VALVE

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO T-STAT

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

BLACK

 

 

 

REVERSING VALVE

FACTORY SET INDOOR MOTOR WIRING

 

BLACK

 

 

 

 

COIL

 

ORANGE

BLACK

RED

 

 

 

ORANGE

 

 

 

 

MODEL

 

 

 

 

 

 

 

 

WIRE

WIRE

WIRE

 

 

 

 

 

 

 

 

 

TO “Y2”

BLUE

 

 

 

 

COMPRESSOR

 

 

X24K

T2

T3

T4

ON

 

 

 

C

 

 

BLUE

 

 

YELLOW

YELLOW

 

X36K

T1

T3

T4

T-STAT

OUTDOOR

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK WIRE IS HIGH SPEED COOLING/HEATING

 

 

MOTOR

 

 

 

 

 

 

 

 

R

 

 

DAUL

 

 

ORANGE WIRE IS LOW SPEED COOLONG/HEATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED WIRE IS AUX. HEATING SPEED (ELECTRIC HEAT)

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

 

 

 

 

 

REFER TO INSTALLATION INSTRUCTIONS FOR CFM DATA

 

 

 

 

 

 

S

 

 

LEGEND:

 

C

 

 

R

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

¢711065«¤

 

HIGH VOLTAGE

 

 

 

BLUE

 

H C

F

7110650

FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

 

LOW VOLTAGE

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0110

Image 18
Contents Q5RF SERIES DO NOT DESTROY. PLEASE READ CAREFULLY ANDKEEP IN A SAFE PLACE FOR FUTURE REFERENCE Single Package Heat Pump - 2 Stage, R-410ARefrigerant Charging Charts for INSTALLER INFORMATIONUSER INFORMATION IMPORTANT SAFETY INFORMATIONOperating Instructions USER INFORMATIONABOUT THE HEAT PUMP Figure 1. Digital ThermostatBefore You Install this Unit INSTALLER INFORMATIONSAFETY INFORMATION GENERAL INFORMATIONCondensate Drainage Figure 2. Drain Trap HEAT PUMP INSTALLATIONAir Duct System ElbowMake sure the filter is readily accessible Installing Return & Supply Air FittingsLocating & Installing the Return Air Assembly Figure 3. Minimum Unit ClearancesLocating & Installing the Supply Dampers Figure 6. Return Air BoxFigure 7. Supply Damper ELECTRICAL CONNECTIONS Pre-ElectricalChecklistFigure 8. Power Entry Line VoltageBlower Speed Overcurrent Protection2-SpeedOutdoor Fan Motor Select Models Ambient Sensor MountingMinimum Time Demand Defrost ControlJumper TerminateINDOOR THERMOSTAT AccessoryAccessory SUB-BASEAnti Short Cycle Timer Test STARTUP & ADJUSTMENTS Pre-StartChecklistStart-UpProcedure Forced Defrost Mode Field TestAdjustment of Refrigerant Charge UNIT MAINTENANCECharging an R-410AUnit in Heating Mode Figure 12. Charging Chart for 3 ton Units Refrigerant Charging Charts forFigure 11. Charging Chart for 2 ton Units Q5RF-X24KCHARGING CHARTFigure 14. Charging Chart for 5 ton Units Refrigerant Charging Charts forFigure 13. Charging Chart for 4 ton Units Q5RF-X48KCHARGING CHARTShaded boxes indicate flooded conditions Q5RF-X48K Q5RF-X60KK¢711065«¤ WIRING DIAGRAM60HZ/SINGLE PHASE 208/230V¢711066#¤ WIRING DIAGRAM60HZ/SINGLE PHASE 208/230V¢709158D¤ COMPONENT FUNCTIONS Low Pressure SwitchHigh Pressure Switch Model Q5RF