Miller Electric OM-220 390F manual Reset Mode, Pulse, Mild Steel, Accu-pulse, 90% Argon, 10% O2

Page 29

6-11. Reset Mode

RST

V

 

NO

A

 

A

Setup Adjust ArcControl

Enter reset mode by turning power On and pressing the Program Push Button until the RST NO message is displayed. RST NO message will not display until after the power-up sequence is completed (approximately 20 seconds).

.Reset mode is not active when Program Lock is enabled.

The reset mode allows the operator to reload factory program settings for all eight active programs in the unit.

.System configuration data will be lost during the Reset operation.

RST

V

YES A

A

Setup Adjust ArcControl

RST

V

YES A

A

Setup Adjust ArcControl

CYCL

V

PWR A

A

Setup Adjust ArcControl

Rotate Adjust knob to change NO

to YES.

Press the Arc Control button to

confirm the reset.

The reset message is displayed for 2 seconds while factory program settings are being reloaded.

During the reset mode the following factory default programs are loaded into the unit:

Program 1

Pulse

 

.035 Mild Steel

 

90% Argon, 10% CO2

Program 2

MIG

 

.035 Mild Steel

 

75% Argon, 25% CO2

Program 3

Accu-pulse

 

.035 Mild Steel

 

90% Argon, 10% O2

Program 4

Pulse

 

.045 Mild Steel

 

90% Argon, 10% CO2

Program 5

MIG

 

.045 Mild Steel

 

75% Argon, 25% CO2

Program 6

Accu-pulse

 

.045 Mild Steel

 

90% Argon, 10% O2

Program 7

Pulse

 

.052 Mild Steel

 

90% Argon, 10% CO2

Program 8

MIG

 

.052 Mild Steel

 

75% Argon, 25% CO2

Cycl Pwr message appears on the display

when programs complete loading.

Turn power off, wait 10 seconds, and turn power back on again to complete the reset operation.

.After Reset is complete, be sure to load

appropriate programs that contain the correct wire size, process, and shielding gas for the welding operation

198 993 / 803 504-B

OM-220 390 Page 25

Image 29
Contents Processes OM-220 390FDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Standards Decwire2/04Directives Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéKeep your head out of the fumes Disconnect input plug or power before working on machine− Definitions Manufacturer’s Rating Label For CE Products Symbols And DefinitionsSpecifications − Installation− Introduction Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Gun Recommendation Table Pin Network Receptacle InformationInstalling And Threading Welding Wire Dual Schedule Switch Option Feeder Display At Power UpPower Source Upper Display Lower Display Voltage Range Net WaitOperational Terms − OperationPower Switch See Section Front Panel SectionsSee Upper Display Program Push ButtonAmps LED Lower DisplayAdjust Knob Feeder Set Up Push ButtonProcessSetup Process Set Up Push ButtonJog/Purge Jog/Purge Push Button Adjust Knob Gun Trigger ReceptacleJog/Purge switch provides the following functions Pulse Reset ModeMild Steel Accu-pulseSequence Parameters − Setting Sequence ParametersSequence Parameters In a Program Routine Maintenance − MaintenanceDiagnostics Indicates a trigger Closed errorTrouble Remedy TroubleshootingDisconnect power before troubleshooting OM-220 390 Circuit Diagram − Electrical Diagram211 005-E − Fig 21 − Fig 10-2 − Parts ListPart Description Quantity Control Box PLG4 Drive Assembly, Wire -1Item Drive Assembly, Wire1.4 mm Metric1.2 mm Page Page Page Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s