5-2. Controls For CE Models
3 | 2 | 1 |
|
|
4
Front Panel
5 | LO | 6 CC | 7 |
HI | CV |
Internal Control Panel
Internal Side View
1Power Control Switch
2Trigger Hold Switch
Depress the upper part of the switch (turns trigger hold On) to weld without holding gun trigger throughout the weld cycle.
To start weld, press and release gun trigger. To end weld, press and release gun trigger.
Depress the lower part of the trigger hold switch to turn trigger hold Off.
3 Purge Switch
Press switch to momentarily ener- gize gas solenoid and purge air from gun, and to adjust shielding gas regulator.
4 Wire Speed Control
Use control to adjust wire speed within range selected by switch.
5 Jog Switch
Use Jog position to momentarily feed welding wire at speed set on Wire Speed control without ener- gizing welding circuit or shielding gas valve.
6 HI/LO Range Switch
Use switch to select high or low wire speed range. High range is 100 to 700 ipm. Low range is 50 to 350 ipm.
7 CC/CV Switch
Use switch to match wire feeder with welding power source output.
Close and latch door.
Ref. 803