SECTION 4 – OPERATION
4-1. Pendant Controls
2
1
3
4
Ref.
Use Nameplates As A Voltage And Amperage Reference Only.
Controls are pendant mounted. An optional remote pendant extension cord is available.
1 Nameplate
Pendant has three nameplates stacked one on top of the other. Each nameplate contains the voltage and amperage range for a differ- ent size flux cored welding wire (for reference only).
Unit is shipped with 1.2 mm wire nameplate
on top. See Section
2 Voltage Control
Use control to set welding power source volt- age at the wire feeder. Numbers are for refer- ence only.
3 Wire Speed Control
Use control to adjust wire feed speed from 0 to 20 meters per minute.
.Match colored bands on voltage and wire speed controls to get an acceptable welding condition.
4 Jog Switch
Use Jog switch to momentarily feed welding wire at speed set on Wire Speed control with- out energizing welding circuit or shielding gas valve.