2-2. Rating Label For CE Products

For label location see Section 4-4.

 

 

S/N:

 

 

U1

24

V

1

50/60

Hz

=

 

 

 

IP 21

 

I1= 10.0A

 

 

 

U2

100 V

I2= 750 A

X 100 %

 

=

 

 

 

 

ST-178 794-A

2-3. Symbols And Definitions

Note Some symbols are found only on CE products.

A

Amperes

V

Volts

U1

Alternating Current

X

Duty Cycle

IP

Protection

Hz

 

 

 

 

 

Degree Of

 

Hertz

 

Primary Voltage

 

Wire Feed

 

 

 

 

 

 

Jog

 

Output

 

Trigger

 

Line Connection

 

Press To Set

U2

Load Voltage

 

Trigger Hold On

 

Trigger Hold Off

 

 

 

 

 

Purge

 

Spot Weld Time

 

Spot Weld

 

Continuous Weld

 

Burnback Time

 

Preflow Time

 

Postflow Time

 

Read Instructions

 

Increase

I1

Primary Current

I2

Rated Current

 

 

 

 

 

 

 

OM-1582 Page 10

Image 14
Contents Description OM-1582Processes From Miller to You Table of Contents Directives StandardsArc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersUN Choc É Lectrique peut tuer Signification des symbolesConsignes DE Securite Lire Avant Utilisation LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux ’EMPLOI Excessif peut Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques + + + DefinitionsSymbols And Definitions Rating Label For CE ProductsIntroduction InstallationSpecifications Site SelectionEquipment Connection Diagrams Gun Recommendation TablePin Information Rear Panel ConnectionsPin Plug Information Motor Start Control Wire Type, Size, And Feed Speed Capability TableMotor Speed Wire Type Wire Size Feed Speed Capability Rotating The Drive Assembly Installing And Threading Welding Wire To adjust drive roll pressure, hold nozzleOptional Equipment DIP Switch Settings Spot Time Range SelectionOption Interface Standard SettingsOperation Front Panel ControlsDisconnect power before maintaining Maintenance and TroubleshootingRoutine Maintenance Overload Protection And Optional Side Panel ControlsTrouble Remedy TroubleshootingDisconnect power before troubleshooting OM-1582 Electrical Diagram Circuit Diagram197 518-A Parts List Main AssemblyOptional Control Box Control Box -1 Item Panel, Front w/Components Panel, Front w/Components -2 Item Control Panel Drive Assembly, Wire Drive Assembly, Wire -1 Items 15 Roll Drive Drive Roll And Wire Guide Kits Fraction MetricKit Roll Wire Size OM-1582 Service SupportOwner’s Record Miller Electric Mfg. Co