Miller Electric 75 manual Reset Mode, Pulse, Mild Steel, Accu-pulse, 90% Argon, 10% O2

Page 30

5-11. Reset Mode

Program

RST

 

Volts

Time

Arc Adjust

 

 

NO

 

 

WFS

Amps

Arc Ctl

Process

 

 

Sequence

Wire Type

 

 

Trigger Control

Gas Type

 

 

Trigger Hold

Process Set up

 

Adjust

Feeder Set Up

Enter reset mode by turning power On and pressing the Program Push Button until the RST NO message is displayed. RST NO message will not display until after the power-up sequence is completed (approximately 20 seconds).

.Reset mode is not active when Program Lock is enabled.

The reset mode allows the operator to reload factory program settings for all eight active programs in the unit.

.System configuration data will be lost during the Reset operation.

Program

RST

 

Volts

Time

Arc Adjust

 

 

YES

 

 

WFS

Amps

Arc Ctl

Process

 

 

Sequence

Wire Type

 

 

Trigger Control

Gas Type

 

 

Trigger Hold

Process Set up

 

Adjust

Feeder Set Up

Program

RST

 

Volts

Time

Arc Adjust

 

 

YES

 

 

WFS

Amps

Arc Ctl

Process

 

 

Sequence

Wire Type

 

 

Trigger Control

Gas Type

 

 

Trigger Hold

Process Set up

 

Adjust

Feeder Set Up

Program

CYCL

 

Volts

Time

Arc Adjust

 

 

PWR

 

 

WFS

Amps

Arc Ctl

Process

 

 

Sequence

Wire Type

 

 

Trigger Control

Gas Type

 

 

Trigger Hold

Process Set up

 

Adjust

Feeder Set Up

Rotate Adjust knob to change NO

to YES.

Press the Arc Control button to

confirm the reset.

The reset message is displayed for 2 seconds while factory program settings are being reloaded.

During the reset mode the following factory default programs are loaded into the unit:

Program 1

Pulse

 

.035 Mild Steel

 

90% Argon, 10% CO2

Program 2

MIG

 

.035 Mild Steel

 

75% Argon, 25% CO2

Program 3

Accu-pulse

 

.035 Mild Steel

 

90% Argon, 10% O2

Program 4

Pulse

 

.045 Mild Steel

 

90% Argon, 10% CO2

Program 5

MIG

 

.045 Mild Steel

 

75% Argon, 25% CO2

Program 6

Accu-pulse

 

.045 Mild Steel

 

90% Argon, 10% O2

Program 7

Pulse

 

.052 Mild Steel

 

90% Argon, 10% CO2

Program 8

MIG

 

.052 Mild Steel

 

75% Argon, 25% CO2

Cycl Pwr message appears on the display

when programs complete loading.

Turn power off, wait 10 seconds, and turn power back on again to complete the reset operation.

.After Reset is complete, be sure to load

appropriate programs that contain the correct wire size, process, and shielding gas for the welding operation

198 993 / 804 587-A

OM-228 956 Page 26

Image 30
Contents Description OM-228 956BProcesses File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers UNE Décharge Électrique peut entraîner la mort LES Fumées ET LES GAZ peuvent être dangereuxIndique un message de sécurité particulier DES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer unIncendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures graves’EMPLOI Excessif peut SUR Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité En ce qui concerne les stimulateurs cardiaques− Introduction − InstallationSpecifications Selecting a LocationConnection Diagram Rear Panel Connections And Rotating Drive Assembly Tools Needed 9/16, 5/8Pin Network Receptacle Information Installing Drive RollsInstallation RemovalInstalling PD Continuous Wire Guides Installing PD continuous wire guides with PD drive rollsRotate guide holder 180 degrees and reinstall Installing Non-PD Old Style Wire GuidesInstalling wire guides with non- PD old-style drive rolls Tools Needed 16, 1/8, 5/32Secure gun by tightening power clamp knob Installing Welding GunInstalling gun with Accu-Mate connection Installing gun without Accu- Mate connectionNo Wire Slip Wire SlipsEnd Of Liner Power Source Upper Display Lower Display Voltage Range Feeder Display At Power UpDual Schedule Switch Options Upper Display Lower Display− Operation Operational TermsGeneral Terms Crater Power SwitchFeeder Set Up PostflowSee See Section Program Volts Time Arc AdjustFront Panel Controls SectionUpper Display Volts Arc AdjustProgram Push Button Upper DisplayLower Display Feeder Set Up Push Button Adjust ControlSequence Trigger Control Trigger Hold Feeder Set Up Process Set Up Push Button Make a selection, rotate the Adjust controlJog/Purge Push Button Adjust Control Gun Trigger Receptacle Welding and to preset gas pressure at the regulatorJog/Purge Mild Steel Reset ModePulse Accu-pulse− Setting Sequence Parameters Sequence Parameters In a ProgramSequence Parameters Disconnect power before maintaining − MaintenanceRoutine Maintenance = Check = Change ~ = Clean = ReplaceDiagnostics Indicates a voltage Sense errorIndicates a polarity error Indicates a line errorIndicates an arc error Indicates a memory CRC PCM errorRMD done message indicates TroubleshootingDisconnect power before troubleshooting Unknown− Electrical Diagram Circuit Diagram211 005-D − Parts List − -3 21 − FigFigures 9-3 Control Box PLG4 Drive Assembly, Wire Drive Assembly, Wire 9-1ItemDrive Assembly, Wire -1Item Wire Size Page Page Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s