Miller Electric 75 manual Jog/Purge Push Button Adjust Control Gun Trigger Receptacle

Page 29

5-10. Jog/Purge

1 Jog/Purge Push Button

2 Adjust Control

3 Gun Trigger Receptacle

2

3

1

803 505-A

Pressing the Jog/Purge switch allows the operator to jog wire without energizing the weld power or gas valve circuit.

The unit provides the ability to jog the wire feeder by means of the gun trigger or the Jog/Purge switch. If the welding arc does not initiate in 3 seconds after the gun trigger is activated, the unit will perform a jog operation for a maximum of 30 seconds. If the gun trigger is still activated after 30 seconds, the jog operation is terminated to prevent complete unspooling of the wire, in the case of a damaged gun. The unit

displays the “ERR STRT“ message to inform the operator that the trigger is activated.

Jog speed can be adjusted by the Adjust control when the unit is jogging wire. The unit displays jog speed when the unit is being jogged.

Jogging can also be accomplished by pressing the Jog/Purge button.

Pressing the Jog/Purge button also allows the operator to purge gas lines before

welding and to preset gas pressure at the regulator.

This unit is equipped with Auto Thread capability. By rocking the switch from purge to jog within 0.5 seconds will automatically feed wire for a factory default setting of 192 in (4877 mm) of wire before stopping. The default feed rate is 700 ipm. These settings can be changed using an optional PDA with File Management software. Pressing the Jog/Purge switch or gun trigger during Auto Threading will terminate the automatic feed operation.

OM-228 956 Page 25

Image 29
Contents Processes OM-228 956BDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Page Marks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Indique un message de sécurité particulier UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux Incendie ou une explosion LE Soudage peut provoquer unDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU D’EXPLO’EMPLOI Excessif peut SUR DES Organes Mobiles peuvent provoquer des blessuresEn ce qui concerne les stimulateurs cardiaques Principales normes de sécuritéSpecifications − Installation− Introduction Selecting a LocationConnection Diagram Tools Needed 9/16, 5/8 Rear Panel Connections And Rotating Drive AssemblyInstallation Installing Drive RollsPin Network Receptacle Information RemovalInstalling PD continuous wire guides with PD drive rolls Installing PD Continuous Wire GuidesInstalling wire guides with non- PD old-style drive rolls Installing Non-PD Old Style Wire GuidesRotate guide holder 180 degrees and reinstall Tools Needed 16, 1/8, 5/32Installing gun with Accu-Mate connection Installing Welding GunSecure gun by tightening power clamp knob Installing gun without Accu- Mate connectionEnd Of Liner No Wire SlipWire Slips Dual Schedule Switch Options Feeder Display At Power UpPower Source Upper Display Lower Display Voltage Range Upper Display Lower DisplayOperational Terms − OperationFeeder Set Up Power SwitchGeneral Terms Crater PostflowFront Panel Controls See Section Program Volts Time Arc AdjustSee SectionProgram Push Button Volts Arc AdjustUpper Display Upper DisplayLower Display Sequence Trigger Control Trigger Hold Feeder Set Up Feeder Set Up Push ButtonAdjust Control Make a selection, rotate the Adjust control Process Set Up Push ButtonJog/Purge Jog/Purge Push Button Adjust Control Gun Trigger ReceptacleWelding and to preset gas pressure at the regulator Pulse Reset ModeMild Steel Accu-pulseSequence Parameters − Setting Sequence ParametersSequence Parameters In a Program Routine Maintenance − MaintenanceDisconnect power before maintaining = Check = Change ~ = Clean = ReplaceIndicates a voltage Sense error DiagnosticsIndicates an arc error Indicates a line errorIndicates a polarity error Indicates a memory CRC PCM errorDisconnect power before troubleshooting TroubleshootingRMD done message indicates UnknownCircuit Diagram − Electrical Diagram211 005-D − -3 21 − Fig − Parts ListFigures 9-3 Control Box PLG4 Drive Assembly, Wire 9-1Item Drive Assembly, WireDrive Assembly, Wire -1Item Wire Size Page Page Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s