5-4. Activating The Dry Charge Battery (If Applicable)
| ! Always wear a face shield, |
| rubber gloves and protective |
| clothing when working on a |
3 | battery. |
|
| Remove battery from unit. | |
| 5 | Vent Caps |
2 | 6 | Sulfuric Acid Electrolyte |
|
| (1.265 Specific Gravity) |
1 | 7 | Well |
Fill each cell with electrolyte to bottom of well (maximum).
! Do not overfill battery cells.
Wait ten minutes and check electro- lyte level. If necessary, add electro- lyte to raise to proper level. Reins- tall vent caps.
8 Battery Charger
! Read and follow all instruc- tions supplied with battery charger.
4
5 A For 30 Minutes
OR+
−
Tools Needed: | 30 A For 12 Minutes |
|
Charge battery for 12 minutes at 30 amperes or 30 minutes at 5 am- peres. Disconnect charging cables and install battery.
.When electrolyte is low, add
only distilled water to cells to maintain proper level.
drybatt1 6/05 −
5-5. Connecting The Battery
. Close door after connecting battery.
. The engine will not run if engine access door is open.
! Connect Negative (−) Cable Last.
+
−
Tools Needed:
1/2 in | Ref. 804 009 / Ref. 222 875 / |
|