BM 1619929L34
Cleaning
To avoid accidents always disconnect the tool from the power supply before cleaning or
performing any maintenance. The tool may be cleaned most effectively with compressed dry air. Always wear safety goggles when cleaning tools with compressed air.
Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not attempt to clean by inserting pointed objects through openings.
Certain cleaning agents ! CAUTION and solvents damage
plastic parts. Some of these are: gasoline, carbon tetrachloride, chlorinated cleaning solvents, ammonia and household detergents that contain ammonia.
Extension Cords
If an extension cord is necessary, a cord with adequate size conductors that is capable
of carrying the current necessary for your tool must be used. This will prevent excessive voltage drop, loss of power or overheating. Grounded tools must use
NOTE: The smaller the gauge number, the heavier the cord.
RECOMMENDED SIZES OF EXTENSION CORDS 120 VOLT ALTERNATING CURRENT TOOLS
Tool’s | Cord Size in A.W.G. | Wire Sizes in mm2 | |||||||
Ampere | Cord Length in Feet | Cord Length in Meters | |||||||
Rating | |||||||||
25 | 50 | 100 | 150 | 15 | 30 | 60 | 120 | ||
| |||||||||
|
|
|
|
|
|
|
| ||
18 | 16 | 16 | 14 | 0.75 | 0.75 | 1.5 | 2.5 | ||
18 | 16 | 14 | 12 | 0.75 | 1.0 | 2.5 | 4.0 | ||
18 | 16 | 14 | 12 | 0.75 | 1.0 | 2.5 | 4.0 | ||
16 | 16 | 14 | 12 | 1.0 | 2.5 | 4.0 | — | ||
14 | 12 | — | — | — | — | — | — | ||
|
|
|
|
|
|
|
|
|
Accessories
* Hammer hauler (Model BH2760VC only)
(*= standard equipment) (**= optional accessories)