Simer Pumps 2300-04, 2355-04, 2305-04, 2310-04 owner manual Safety / General Information

Page 2

Safety / General Information

2

READ AND FOLLOW

SAFETY INSTRUCTIONS!

Carefully read and follow all safety instructions in this manual and on pump.

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.

warns about hazards that will cause serious personal injury, death or major property damage if ignored.

warns about hazards that can cause serious personal injury, death or major property damage if ignored.

warns about hazards that will or can cause minor personal injury or property damage if ignored.

The label NOTICE indicates special instructions which are important but not related to hazards.

Keep safety labels in good condition.

Replace missing or damaged safety labels.

DESCRIPTION

These Submersible Utility Pumps are designed for drain- ing water from basement floors, stock tanks, window wells, boats, flat roofs and cisterns. The units are equipped with a 3-prong grounding-type power cord. The shaded-pole motors are oil filled and sealed for cooler operation. The sleeve bearings on the motor shaft never need lubrication. Automatic reset thermal protection.

NOTICE: This unit is not designed for applications involv- ing salt water or brine! Use with salt water or brine will void warranty.

SPECIFICATIONS

Power supply required

...............................

115V, 60 HZ.

Liquid Temp. Range

Less Than 120°F (50°C)

Individual Branch Circuit Required (min.)

15 Amps

Pump Discharge:

1-1/4" NPT

Adapter:

3/4" Garden Hose

Risk of fire or explosion. Do not use in explosive atmospheres.

Pump water only with this pump.

NOTICE: This unit is not designed as a waterfall or foun- tain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.

Do not use where water recirculates.

Not designed for use as a swimming pool drainer.

PERFORMANCE

GPH (LPH) AT TOTAL FEET (M)

Model

0

5

10

15

20

25

No.

(0)

(1.5m)

(3m)

(4.6m)

(6.1m)

(7.6m)

 

CAPACITY GALLONS(L)/Hour

 

2300-04

1,320

1,170

1,020

810

510

2305-04

(4,997)

(4,429)

(3,861)

(3,066)

(1,931)

(–)

2310-04

 

 

 

 

 

 

2355-04

2,160

1,740

1,620

1,260

720

60

(8,160)

(6,600)

(6,120)

(4,790)

(2,700)

(240)

ELECTRICAL & SWITCH

SPECIFICATIONS

 

 

Motor

Individual

Model

 

Full Load

Branch Circuit

No.

HP

Amps

Req. (Amps)

 

 

 

 

2300-04

1/4

5.6

10

2305-04

1/4

6.0

10

2310-04

1/4

5.6

10

2355-04

1/3

10.0

15

GENERAL SAFETY INFORMATION

Electrically powered utility pumps normally give many years of trouble-free service when correctly installed, maintained, and used. See the “Troubleshooting Chart” in this manual for information about common utility pump problems and remedies. For more information, see your retailer, or call Simer customer service at 1-800-468-7867 or 1-800-546-7867.

1.Know the pump application, limitations, and poten- tial hazards.

2.Do not use this pump in water with fish present. If any oil leaks out of the motor it can kill fish.

3.Disconnect the power before servicing.

4.Release all the pressure within the system before ser- vicing any component.

5.Drain all the water from the system before servicing.

6.Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly caus- ing personal injury and/or property damage.

7.Check hoses for a weak or worn condition before each use, making certain that all connections are secure.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 2
Contents MOD -04, 2305-04, 2310-04 Submersible Utility PumpsSafety / General Information Operation Installation / OperationInstallation Airlocks TroubleshootingOperation Repair Parts Model Numbers 2300-04 2305-04Warranty Limited WarrantyCaractéristiques Sécurite / Consignes généralesLire Toutes CES Instructions ET LES Suivre RendementInstallation / Fonctionnement FonctionnementBouchon Dair FonctionnementRecherche des pannes Pièces de rechange Numéros de modèle 2300-04 2305-04Garantie Garantie LimitéeSeguridad Operación Información general / InstalaciónInstalación Bolsas DE Aire Airlock Instalación / OperaciónLocalización de fallas Piezas para reparaciones Modelos números 2300-04 2305-04Garantía Garantía Limitada

2310-04, 2300-04, 2305-04, 2355-04 specifications

Simer Pumps has established itself as a reliable name in the field of water transfer and quality performance pumps. Among their range, the Simer Pumps 2310-04, 2300-04, 2355-04, and 2305-04 models stand out for their impressive features and advanced technologies tailored to meet a variety of pumping needs.

The Simer 2310-04 model is designed for efficient performance in water movement applications. It features a robust motor that provides high efficiency and low energy consumption, making it ideal for residential and light commercial uses. This model is particularly noted for its durable construction that ensures longevity and resistance to wear and tear. The integrated thermal overload protection is an added advantage, safeguarding the pump from overheating and ensuring safety during operation.

Next in line, the Simer 2300-04 is a versatile pump known for its reliable operation. This model is especially effective in transferring clear water and is suitable for various applications, including irrigation, water supply, and construction sites. It boasts a compact design that allows for easy installation and relocation. In addition, its corrosion-resistant materials extend its lifespan, making it a cost-effective choice for users who demand durability without compromising performance.

The Simer 2355-04 model takes things further with enhanced features, catering to more demanding applications. This model is equipped with a powerful motor that allows for higher flow rates, making it ideal for heavier tasks. Its unique impeller design minimizes turbulence and maximizes efficiency, ensuring that water is moved quickly and effectively. Additionally, the pump has been engineered to offer quiet operation, reducing noise pollution—a significant advantage for urban or residential settings.

Lastly, the Simer 2305-04 model combines reliability with cutting-edge technology. It is characterized by its self-priming capabilities, ensuring ease of use by eliminating the need for manual priming before operation. This model also features adjustable flow settings, allowing users to optimize performance according to specific needs. The inclusion of a high-efficiency motor not only enhances performance but also contributes to lower energy costs—an essential factor for eco-conscious consumers.

With these models, Simer Pumps continues to push the boundaries of efficiency, performance, and user-friendliness. Each pump is designed with end-user needs in mind, ensuring that customers receive a product that meets their specific requirements while providing excellent value. Whether for light domestic use or more intensive applications, Simer's range of pumps delivers on the promise of quality and reliability.