1. Specifications
1-1 Unit Specifications
| MODEL No. |
| Indoor Unit |
|
|
|
|
|
| XHS2432 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Outdoor Unit |
|
|
|
|
| CH2432 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| POWER SOURCE |
|
|
|
|
|
|
| 230 - 208 V / 1 Phase / 60 Hz | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| PERFORMANCE |
|
|
|
|
| Cooling |
|
| Heating | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Capacity* | (17°F)** |
| BTU / h | 24,000 |
| 23,400 |
| 25,000 |
| 24,300 | |||
|
|
|
|
|
|
|
|
|
|
| 16,400 |
| 15,800 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Moisture removal (High) |
|
| Pints / h | 8.6 |
| 8.4 |
|
| — | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Air circulation (Hi) |
|
| cu.ft. / min. |
|
|
|
| 540 / 510 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||
| S.E.E.R. (H.S.P.F.) |
|
| BTU / Wh | 10.0 |
| 10.2 |
| (7.0) |
| (7.0) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Voltage rating |
|
|
| VAC | 230 |
| 208 |
| 230 |
| 208 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Available voltage range |
|
|
| VAC |
| 187 - 253 |
|
| 187 - 253 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Running amperes |
|
|
| A | 11.2 |
| 11.6 |
| 11.7 |
| 12.3 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Max. running amperes |
|
|
| A | — |
|
| — |
| — |
| — | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Power input* |
|
|
| W | 2,450 |
| 2,350 |
| 2,500 |
| 2,450 | ||
|
|
| (17°F)** |
|
|
|
|
|
|
|
| 2,150 |
| 2,020 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| kW | — |
|
| — |
| — |
| — | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Maximum fuse size |
|
|
| A |
|
|
|
| 30 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FEATURES |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Controls |
|
|
|
|
|
|
| Microprocessor |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||
| Fan speeds Indoor / Outdoor |
|
|
|
|
|
|
| 3 and Automatic control / 2 (Auto) | |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
| Timer |
|
|
|
|
|
|
| ON / OFF | |||||
|
|
|
|
|
|
|
|
|
|
| ||||
| Air deflection | Horizontal / Vertical |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||||
| Air filter |
|
|
|
|
| Washable, easy access, long life fiter (2,500 hr) | |||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
| Operation sound |
| Indoor |
|
| dB - A |
| 37 / 35 / 31 |
|
| ||||
| Hi / Me / Lo |
| Outdoor - Hi |
|
| dB - A |
|
|
|
| 53 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
| Refrigerant control |
|
|
|
|
|
|
| Electronic Refrigerant Control Valve | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| REFRIGERANT PIPING |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Limit of piping length |
|
| ft. | (m) |
|
|
|
| 165 (50) |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Limit of piping length at shipment |
|
| ft. | (m) |
|
|
|
| 100 (30) |
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||||
| Limit of elevation difference |
|
| ft. | (m) |
| Outdoor unit is higher than indoor unit: 165 (50) | |||||||
| between the two units |
|
|
|
|
| Outdoor unit is lower than indoor unit: 100 (30) | |||||||
| Refrigerant piping |
| Narrow pipe |
| in. (mm) |
|
|
|
| 1 / 4 (6.35) |
|
| ||
| Flare type |
| Wide pipe |
| in. (mm) |
| 3 / 4 (19.05) |
|
|
1
2
3
4
SM830076