!. TROUBLE SHOOTING
General Trouble Shooting
CA U TION:
Always disconnect the dishwashers from the electrical power source before adjusting or replacing components.
| , +pROBLEM | ++- |
|
|
|
|
| POSSIBLE | CAUSE |
|
|
|
|
|
| ACTION |
|
| |||||||||
Dishes | not | clean, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Refer | to | introductory |
| section | at | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| beginning | of | this | manual |
|
| ||||
Dishwasher | will | not |
| 1. | No power | to dishwasher. |
|
|
| 1, | Check | electrical | outlet | or | connection | ||||||||||||
operate | when turned | om |
|
|
|
|
|
|
|
|
|
|
|
|
| to junction | box | on |
|
| |||||||
|
|
|
|
| 2. | Open circuit | between | power | source |
| 2 | Check | wiring | and/or | power | cords | |||||||||||
|
|
|
|
|
| and | timer |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 3, | Loose | terminal | connections |
| at door |
| 3_ | Repair | as needed_ |
|
|
|
|
| ||||||||
|
|
|
|
|
| switch | and/or | timer | terminals, |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
| 4. | Defective | door | switch |
|
|
|
| 4,, | Check | continuity |
|
|
|
|
|
| ||||||
|
|
|
|
| 5. | Defective | selector | switch., |
|
|
| 5+ | Check | continuity |
|
|
|
|
|
| |||||||
|
|
|
|
| 6, | Defective | timer | motor | circuits. |
| 6 | Refer | to | Timer | Testing° |
|
| ||||||||||
|
|
|
|
| 7 | Defective | start | switch, |
|
|
| 7+ | Applies | to models | with | a rapid | advance | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| timer. | Check continuity, |
|
|
| |||||
|
|
|
|
| 8, | Main | motor |
| defective,, |
|
|
|
| 8 | Refer | to | Motor | Testing |
|
|
| ||||||
Dishwasher | automatically | 1+ | Start sw_tch contacts | sticking | closed, | 1, | Replace | start | s_,itcho |
|
|
| |||||||||||||||
repeats | with | door | latched |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 2. | A grounded |
| timer | motor | combined | with |
| Replace | timer, | Refer | to lnstatlation | |||||||||||
|
|
|
|
|
| reverse | potarity | connection |
| at junction |
| Instructions | for | proper | electrica_ | ||||||||||||
|
|
|
|
|
| box | or | walt | receptacle | causing the | "hot" |
| connection | and | grounding | of | power | ||||||||||
|
|
|
|
|
| side | of | the |
| circuit | to | bypass | "'off" |
|
| receptacfes. |
|
|
|
|
|
|
| ||||
|
|
|
|
|
| switches | in | the | timer |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
,J
3, Grounded thermostat with reverse polarity
4+ Broken slides inside of selector switch (rapid advance timer onfy)+
Dishwasher | runs with | 1. | Door | switch | defective+ |
door open, |
|
|
|
|
|
|
| 2, | Terminals shorted to each other at the | ||
|
|
| door | switch, |
|
3.Latching handle turned to the "ON" position
4 Grounded electrical component combined with reverse polarity
connection at junction box or wall receptacle,
3Replace thermostat+ Check electrical connection,
4.Refer to wiring diagram and check selector switch circuitry.
f.Check continuity'.
2.Replace defective parts,
3+ Check safety tab, which prevents turning handle into run position with door open
4 Replace defective component, Refer
to Installation ]nstruct]on for proper
electrica_ connection and grounding of power receptacle.
85