Kenmore 808353 manual Side, Water Inlet Valve

Page 24

DELIVER

TUBE

HOSE

STEP 2

STEP

FIGURE20

Water Inlet Valve

The water inlet valve is solenoid operated and when energized permits a constant controlled flow of water to enter the dishwasher tub, The valve is designed to operate over a pressure range of 20 pounds per square inch minimum to 120 pounds per square inch maximum, The frequency and length of Lime the valve is operating is controlled by the timer, Water inlet valves differ only in amount of water they deliver (flow rate) which is governed by the aperture size in the flow washer See Figure 21, Some models may have a three orifice flow washer

IDENTIFICATION MARKINGS

CONCAVE

"_WATER

'__1 '_-" FLOW

SIDE

FIGURE21

21

Image 24
Contents Automatic Dishwashers We Service Wh,t We Sell If ever you need us -- were available You Can Count On UsSears t Contents Introduction WATER, Detergent and the Automatic Dishwasher Removal and Control of Hard Water FilmExtremely hot water Possible Cause & Solution FilmingBronze Tarnish on Silverware Black Marks on DinnerwareCleaningmineraldepositsfromporcelainsurfaces Attach Screws Access PanelInstallation Drain Hose Connected to Disposer Or y Branch2HOLE or Larger Sink X,,T LeftDrain Hoseconnectionto Sink Drain Drain Hose Connection Through FloorCutting Access Holes Inlet Valve ,JUNCTION BOX AssemblyCircuit Conductorground Wire Green Ground ScrewElectrical GROUND1NGINSTRUCTIONSReen Ground Screw Shut OFF VA LV EHOT Wate Line Trap P or Above DrainHOW to POSITION, ALIGN, and LEVEL, Your Dishwasher Sink AI Left Sink AT RightTWO Ways to Anchor Your Dishwasher Two Level Wash Feature Wjash SystemSwitch Testing Water Charge LevelSpray Arm Assembly TttttThree Level Wash System PushlodgedparticlesBearing Assembly Removal of Mtddle Spray ArmRemoval of Upper Spray Arm Only Side Water Inlet ValveWasher Atmospheric PRESSURE£ B Plunger DiaphragmPlunger Hole Line Water Pressure Flow WasherTesting Sen/zcingMetal Washer Flow Plastic Retainer Curved Side Screen Sealer Washer45 sec MarkingPage WA1ERiNLETASSEMBLY Side Water Inlet, Steam Trap and VentingTowaterinletvalve PlasticnutMotor and Pump Assembly Assembled Inner DoorExit Flow of Moist AIR During DRY Cycle Vent Pump Assembly PU M P PlateBottom of Relay Main Motor and RelayPage System Uses Same Pump Housing aS u L Level Tower Pump 5y,srem ThisHousin With the recirculating Osed Off For this Reason He bwer Utltz,es a. lowerTimer Testing the Motor and RelayMotor Main or Run Winding Check Position RelaystartTAR. T .,..BLUE-ORANGE Timer t- Relay Motor Start Circuit Wash and Rinse CycleCheck the voltage as shown in Position C Motor 5tart Circuit Drain Cycle115 Volt Supply Motor Start RelayWash Or Connected Directly to Terminal Block of DishwasherTerminal WAs.ER CA U T/OiM Center Motor Shaft with Pump Housing With Service Tool ROD Motor nstaltationInstall Ihese Screws First TUB Hoses and Couplers No TEHose and Coupler Assembly 8 compact model Faucet Coupler RingSleevegasket Dispensers Detergent DLpenser- B/-Metal OperatedDescription Wetting Agent Dispenser Bi-Metal Operated Fill Neck Scoop Wetting Agent LiquidInto Fill Neck Drainsback .J NtosuppFIGUP,E Timers CAM SwitchCAM MotorSelector Switches Checking The 5-Button SwttchThermostats and Temperature Indicators Sam-Wash or High Temperature Wash/Rin.se ThermostatMylar Jacket Checking Thermostat OperationFigurego Iii ii!ii!!i!i IiiiiiiiiSanM4/ash Delay Circuit 4tfi RinseDRY Water Heat Option Hot RinseSanitize Delay Light Circuit Power Sani Wash Cycle Selector Page FIGUREG3C Page Door and Float Switches Door Latches and SwitchesTCH on FLO Switch Cycle Charts Ester Line Charts ExampleFill Phase Normal Cycle Page Relay Switch Opens After Motor Starts First Wash Normal CycleVoltage Checks Continuity Check Door Assemblies One Piece Outer Door Control PanelTwo Piece Outer Door Control Panel Anti Tilt Assembly38 Portable Models Arm Replacement 8 Dishwashers£RING Racks END CAP RackTub Gaskets Upper Front Lower Rear RollerTo Replace Page Cord Reel Caster Replacement Potlable Dishwashers CastersTubs Drying System Convection MethodForced Air Method SeRE A sEMBL Checking Blower OperadonHeating Elements Heating ElementOperation Eatersymbol Heater TestingHot Dry Cool Dry Power Miser SWHch Power Miser Orange BUS TimerPower Miser Circuits Single Pole Double Throw Switch Heater WhiteBlower Trouble Shooting General Trouble ShootingCheck selector switch per wiring diagram Turn knob until pitot light burns never turn into fill Instructions Motor Shaft Seal are Lever Water Leaks Door liner806863 806565807042 806898DIV 22 Source 587 Part Noo