FIGURE48
Connecting a voltmeter in series with the Bi-Metal as shown in Figure 48 will permit a quick check of the circuit If the circuit is good, tine voltage will be indicated when the timer is advanced to the Detergent Dispenser Inclement with th'edishwasher connected to a power source_ The Bi-Metal will not heat with the voltmeter connected, due to the high resistance of tile meten
Failure of the Bi-Metal to operate can usually be traced to a poor connection, faulty contact or an open iead The Bi-Metal itself is a highly reliable component, If the circuitry is found to be satisfactory, the latching surfaces of the cam and trigger should be checked for roughness,
CAUTION: Do not apply line voltage across the Bi.,Metal, as this would destroy it,
The Bi-Metal leaf is an integral part of the electric circuit, tf it becomes necessary to touch the leaf for any _eason, turn off the power to the dishwasher Although the Bi-Metal is a tow voltage component, it is possible to have a 120 volt potential from _he Bi-Metal to ground when the Bi-Metai circuit is open
| | | Ref, | | |
| | | No, | Description |
| | | 1, | Bi-Metal Trigger |
| | | 2 | Screw |
| | | 3 | Screw |
| | | 4 | Cam | |
| | | 5 | Roll | Pin-Cam |
| | | 6o | Spring-Cam |
| | | 7 | Spring-Cam-Compression |
| | | 8 | Nut | |
| | | 9 | Bracket-Actuator |
| | | 10 | Washer |
| | | 11 | Bushing |
| | | 12 | "0" | Ring |
| 14 | 15 | 13 | Shaft | |
| 14. | Cup- Detergent |
| | |
| 3 | | 15, | Cover-Cup |
| | 16 | "0" | Ring |
| | |
FIGURE49