RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT)
NAMEPLATE |
| EXTENSION CORD LENGTH |
| ||||
AMPERES |
|
| |||||
|
|
|
|
| |||
(at full load) |
|
|
|
|
| ||
25 Feet | 50 Feet | 75 Feet | 100 Feet | 150 Feet | |||
|
| ||||||
0 – 2.0 | 18 | 18 | 18 | 18 | 16 | ||
2.1 | – 3.4 | 18 | 18 | 18 | 16 | 14 | |
3.5 | – 5.0 | 18 | 18 | 16 | 14 | 12 | |
5.1 | – 7.0 | 18 | 16 | 14 | 12 | 12 | |
7.1 – 12.0 | 18 | 14 | 12 | 10 | - | ||
12.1 | – 16.0 | 14 | 12 | 10 | - | - | |
16.1 | – 20.0 | 12 | 10 | - | - | - |
TABLE A * Based on limiting the line voltage drop to five volts at 150% of the rated amperes.