Sanyo CL4232 Other Component Specifications Outdoor Unit, Model No C4232, Power Relay

Page 16

2. SPECIFICATIONS

(3)Other Component Specifications

(B)Outdoor Unit

 

MODEL No.

 

C4232

 

 

 

 

 

Compressor Motor Magnetic Contactor

FC - 2SUL

 

 

 

 

 

Coil rated

 

AC 240 V, 60 Hz

 

 

 

 

 

Coil resistance (at 68 °F)

Ω

350 ± 10 %

 

 

 

 

 

Contact rated (Main)

 

AC 240 V, 35 A

 

 

 

 

 

 

Contact rated (Auxiliary)

 

AC 240

V, 3 A

 

 

 

 

 

Power Relay

 

HH62S

 

 

 

 

 

Coil rated

 

AC 240 V, 60 Hz

 

 

 

 

 

Coil resistance (at 77 °F)

kΩ

17.2

 

 

 

 

 

 

Contact rated

 

AC 220

V, 5 A

 

 

 

 

 

Thermostat (Coil sensor)

 

YTB - 4U305F

 

 

 

 

 

 

Operating Temperature

°F

79 ± 3

OFF

 

 

 

75 +13

ON

 

Contact rated

 

200 to 240 V, 1 A

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

SM830078

– 16 –

Image 16 Contents
XS4232 C4232 Indoor Unit Outdoor UnitTS4232 …In a Room Please Read Before Starting…In Moist or Uneven Locations Table of Contents Introduction Read Me First XS4232, TS4232 / C4232 Operating RangeXS4232, TS4232 / CL4232 Unit Specifications SpecificationsModel No Indoor Unit XS4232 Outdoor Unit C4232 Model No Indoor Unit XS4232 Outdoor Unit Cooling Low ambient control Major Component Specifications Indoor Unit Model No TS4232 Source Auto louver motor Major Component Specifications Outdoor Unit Controller P.C.B. Assy Model No CL4232 SourceHeat exchange Other Component Specifications Indoor Unit Model No XS4232 Power TransformerFloat switch Thermistor Coil sensorModel No TS4232 Power Transformer Other Component Specifications Outdoor Unit Power RelayModel No C4232 Thermostat Coil sensorModel No CL4232 Dimensional Data Indoor Unit XS4232Indoor Unit TS4232 19/32Outdoor Unit C4232, CL4232 Cooling Capacity Indoor Unit XS4232 Outdoor Unit C4232, CL4232208V / 1 phase / 60Hz Indoor Unit TS4232 Outdoor Unit C4232, CL4232 800 CFM Performance Charts Operating Current Indoor Unit XS4232 Outdoor Unit C4232230V 208VOperating Current Indoor Unit TS4232 Outdoor Unit C4232Operating Current Indoor Unit XS4232 Outdoor Unit CL4232 Operating Current Indoor Unit TS4232 Outdoor Unit CL4232 Low Pressure Suction Outdoor ambient temp. F C Indoor temp. F C 104 AIR Throw Distance Chart Model XS4232Refrigerant Flow Diagram Indoor Unit 4232 Type Outdoor Unit C4232, CL4232Installation Instructions Tubing LengthSelecting the Installation Site AvoidCase of multiple installations Recommended outer dimensions of wind shield field supply Air Discharge Chamber for Top DischargeWind Shield for CL Model GeneralWiring System Diagram Electrical Wiring General Precautions on WiringOutdoor Unit C, CL models Single-phase 60 Hz, 208 / 230 Electrical Data Indoor model TS4232 / Outdoor model C4232, CL4232Electric Wiring Diagram Electrical Wiring DiagramsSchematic Diagram 854-2-5268-593-00-0 TS3632 RY1~RY5 Diagram Compressor Motor Electric Wiring Diagram CL4232 Outdoor UnitFMO1 Room Temperature Control Processes and FunctionsFreeze Prevention Drain Pump ControlOutdoor Fan Speed Control C4232 Type CL4232 TypeService Procedures 1340XS Check remote control unit There is a possibility of short circuitCheck compressor motor protectors High pressure switch 63PH Check Operation selector switch in the indoor unitTransformer in indoor unit Check fuse on the P.C.B. Ass’y in the indoor unit Check. auxiliary relay Y or 2YXS Type only Check set temperature Check Cool / FAN selector switch in the remote control unitOutdoor Unit does not Run Check compressor motor magnetic contactor Check indoor unit P.C.B Check outdoor unit P.C.B CL3632 TypeIndoor Unit does not Run Indoor fan and louver motor do not runSome Part does not Operate. A. Indoor fan does not run Louver motor does not runOutdoor Fan does not Run Outdoor Fan does not Run for CL4232 Compressor does not RunPoor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Operation of Major Electrical PartsPower Supply Wires Measurement of Insulation Resis- tance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitCheck for continuity using a multimeter as shown in Fig Continuity of fuse on P.C.B. Ass’yMethod Used to Replace Fuse on PCB Ass’y Room temp. sensor KTEC-35Central Region