Sanyo C4232, CL4232 service manual Schematic Diagram

Page 40

10. ELECTRICAL WIRING DIAGRAMS

(1) Indoor Unit

1 XS4232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Schematic Diagram

 

 

CR-TS2432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller

 

 

4P-1

 

 

 

 

 

 

 

2

 

 

 

 

3

 

 

 

 

 

 

PRY

 

 

 

 

 

 

F1

 

 

 

 

 

1

2

SEC

 

 

 

 

 

 

 

 

2

 

 

 

(3A)

 

 

RY1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

 

W/

 

 

 

 

 

 

 

 

 

 

 

IND

 

 

 

 

 

 

 

1

 

1

LESS

 

 

 

 

 

 

 

 

 

7

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR1

 

 

 

4P-4

RY4

RY3

RY5

RY2

 

 

RY2

 

 

 

1

1

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

SW

 

 

 

 

 

 

 

 

 

2

2 SW

 

 

 

 

H

M

L

 

 

 

ASSY

 

 

 

 

 

 

 

3

3

 

 

1

1

5

3

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

6

5

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

RY1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

FS

 

 

 

 

 

FMI

 

 

 

FS

 

 

 

LM

DP

 

1

RY2

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

RY3

 

LM

 

 

 

 

 

 

 

2

1

49FMI

 

 

TH1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC1

 

 

TH1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY4

 

2

 

 

 

2

 

 

 

8

 

 

 

Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49FI

RY5

 

DP

 

TH2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

TH2

1

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

Room

 

 

3

3

 

 

1

 

 

 

 

 

4P-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbols

 

 

Description

Symbols

 

Description

 

 

FMI

Indoor Fan Motor

TH1

Thermistor (Indoor Coil)

49FI

Indoor Motor Thermal Protector

TH2

Room Thermistor

 

 

 

 

RC1

Running Capacitor

CR-TS2432

Indoor Controller

 

 

 

 

F1

Fuse

IND

Indicator Lamp Assy

 

 

 

 

DP

Drain Pump

SW

Switch Assy

 

 

 

 

LM

Auto Louver Motor

 

Terminal Plate

 

 

 

 

TR1

Power Transformer

 

Connector

 

 

 

 

RY1-RY5

Auxiliary Relay

 

Terminal

 

 

 

 

FS

Float Switch

 

 

S 854-2-5268-578-00-0 (XS3632)

SM830078

– 40 –

Image 40
Contents XS4232 C4232 Indoor Unit Outdoor UnitTS4232 …In a Room Please Read Before Starting…In Moist or Uneven Locations Table of Contents Introduction Read Me First XS4232, TS4232 / C4232 Operating RangeXS4232, TS4232 / CL4232 Unit Specifications SpecificationsModel No Indoor Unit XS4232 Outdoor Unit C4232 Model No Indoor Unit XS4232 Outdoor Unit Cooling Low ambient control Major Component Specifications Indoor Unit Model No TS4232 Source Auto louver motorMajor Component Specifications Outdoor Unit Controller P.C.B. Assy Model No CL4232 SourceHeat exchange Other Component Specifications Indoor Unit Model No XS4232 Power TransformerFloat switch Thermistor Coil sensorModel No TS4232 Power Transformer Other Component Specifications Outdoor Unit Power RelayModel No C4232 Thermostat Coil sensorModel No CL4232 Dimensional Data Indoor Unit XS4232Indoor Unit TS4232 19/32Outdoor Unit C4232, CL4232 Cooling Capacity Indoor Unit XS4232 Outdoor Unit C4232, CL4232208V / 1 phase / 60Hz Indoor Unit TS4232 Outdoor Unit C4232, CL4232 800 CFM Performance Charts Operating Current Indoor Unit XS4232 Outdoor Unit C4232230V 208VOperating Current Indoor Unit TS4232 Outdoor Unit C4232Operating Current Indoor Unit XS4232 Outdoor Unit CL4232 Operating Current Indoor Unit TS4232 Outdoor Unit CL4232 Low Pressure Suction Outdoor ambient temp. F C Indoor temp. F C 104 AIR Throw Distance Chart Model XS4232Refrigerant Flow Diagram Indoor Unit 4232 Type Outdoor Unit C4232, CL4232Installation Instructions Tubing LengthSelecting the Installation Site AvoidCase of multiple installations Recommended outer dimensions of wind shield field supply Air Discharge Chamber for Top DischargeWind Shield for CL Model GeneralWiring System Diagram Electrical Wiring General Precautions on WiringOutdoor Unit C, CL models Single-phase 60 Hz, 208 / 230 Electrical Data Indoor model TS4232 / Outdoor model C4232, CL4232Electric Wiring Diagram Electrical Wiring DiagramsSchematic Diagram 854-2-5268-593-00-0 TS3632 RY1~RY5 Diagram Compressor Motor Electric Wiring Diagram CL4232 Outdoor UnitFMO1 Room Temperature Control Processes and FunctionsFreeze Prevention Drain Pump ControlOutdoor Fan Speed Control C4232 Type CL4232 TypeService Procedures 1340XS Check remote control unit There is a possibility of short circuitCheck compressor motor protectors High pressure switch 63PH Check Operation selector switch in the indoor unitTransformer in indoor unit Check fuse on the P.C.B. Ass’y in the indoor unit Check. auxiliary relay Y or 2YXS Type only Check set temperature Check Cool / FAN selector switch in the remote control unitOutdoor Unit does not Run Check compressor motor magnetic contactor Check indoor unit P.C.B Check outdoor unit P.C.B CL3632 TypeIndoor Unit does not Run Indoor fan and louver motor do not runSome Part does not Operate. A. Indoor fan does not run Louver motor does not runOutdoor Fan does not Run Outdoor Fan does not Run for CL4232 Compressor does not RunPoor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Operation of Major Electrical PartsPower Supply Wires Measurement of Insulation Resis- tance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitCheck for continuity using a multimeter as shown in Fig Continuity of fuse on P.C.B. Ass’yMethod Used to Replace Fuse on PCB Ass’y Room temp. sensor KTEC-35Central Region

CL4232, C4232 specifications

The Sanyo C4232 and CL4232 are renowned models in the realm of electronics, particularly celebrated within the realm of consumer appliances and consumer electronics. As part of Sanyo’s esteemed lineup, these models are crafted with both functionality and performance in mind, appealing to a wide demographic of users.

One of the standout features of the Sanyo C4232 and CL4232 is their energy efficiency. Both models leverage advanced technology to minimize power consumption, making them environmentally friendly options. This is particularly beneficial in today’s world, where sustainable practices are becoming increasingly vital. Users can enjoy the performance of these devices without the guilt of excessive energy expenditure.

In terms of design, the Sanyo C4232 and CL4232 showcase a sleek and modern aesthetic, incorporating user-friendly interfaces that simplify operation. The control panels are intuitively designed, allowing users to navigate options effortlessly. This focus on user experience is evident in the thoughtfulness of the layout and accessibility of controls, making these models suitable for consumers of all ages.

The Sanyo C4232 and CL4232 are also equipped with a variety of advanced features that enhance their usability. For instance, many models come with multiple settings that cater to different user needs, whether it be cooking, cooling, or heating. This versatility ensures that the units can effectively meet diverse requirements, making them indispensable in any household.

Another key characteristic of these models is their durability. Sanyo products are known for their robust construction and long-lasting performance. By utilizing high-quality materials and rigorous testing processes, Sanyo ensures that both the C4232 and CL4232 can withstand the rigors of daily use, providing consumers with reliable service over time.

Modern technology is integrated throughout the Sanyo C4232 and CL4232 models, including smart functionalities that align with contemporary lifestyles. Many of these appliances can be connected to home networks, allowing for remote control and monitoring via mobile devices. This connectivity not only enhances convenience but also allows users to manage their energy consumption efficiently.

In summary, the Sanyo C4232 and CL4232 offer a blend of efficiency, user-friendly design, durability, and modern technology. These models exemplify Sanyo’s commitment to providing practical and reliable solutions for consumers, making them worthy investments for any household looking to enhance their quality of life through innovative electronics.